40
F44
Not used
F45m
Not used
F48
Not used
F49
OFF*
It enables the buzzer warning beep when the motor thrust power limit is reached (refer to the paragraph
"Functional testing")
S
ON
It disables the buzzer warning beep when the motor thrust power limit is reached.
F50
Not used
F51
Not used
F52
Not used
F53
Not used
F54
Not used
F55
Not used
F56
Not used
F57
Not used
F58
Not used
F59
Not used
F60
Not used
F61
Not used
F62
Not used
F63
Not used
F64
Not used
F65
Not used
F66
Not used
F67
Not used
F68
Not used
F69
Not used
F70
Not used
F71
Not used
F72
Not used
F73
OFF*
Opening leaf braking stage start in advance with relation to the end of the manoeuvre.
S
ON
Opening leaf braking stage start corresponding to the last degrees of the manoeuvre.
F74
Not used
F75
Not used
F76
Not used
F77
OFF*
Privacy function disabled
ON
Privacy function enabled (refer to the paragraph "PRIVACY FUNCTION")
F78
Function
enabled if the
function F77
= ON
OFF*
for electromagnet not equipped with open/closed status sensor (factory setting).
The Neptis Plus automation automatically detects the closed door status.
ON
ONLY READ IF YOU INSTALLED AN ELECTROMAGNET EQUIPPED WITH AN OPEN/CLOSED STATUS SENSOR
(not supplied by Label)
for electromagnet equipped with open/closed status sensor. Connect the N.O. output contact of the
electromagnet built-in status sensor to the AUX1 input of the PWB control unit to detect the closed door
status.
F79
Function
enabled if the
function F77
= ON
OFF
The signaling light (D) is steadily green while the door is moving and waiting for the door lock command.
ON*
The signaling light (D) alternately switches between red and green; it flashes slowly while the door is
moving, and fast when the door is waiting for the door lock command.
When the door is closed the light is always steadily red.
F80
OFF*
Cyclic function OFF
ON
Cyclic function ON.
It activates the continuous door opening and closing cycle; it is used only for operation tests or durability
tests.