37
FUNCTION TABLE
1
Function to be set in the menu "Initial Set-up" of the digital selector before door start.
*
Default setting of the function.
"
For dual leaf swing door. In the Slave column are marked with the letter S the functions that must be set
separately on the Slave automation in case of dual leaf door. The other functions not marked with S are
set only on the Master automation.
FUNCTION
STATE
EXPLANATION
"SLAVE
F01
1
OFF*
Selection of the work program switch: embedded manual selector or key mechanical selector
EV-MSEL
ON
Selection of the work program selector: digital selector ET-DSEL or T-NFC.
F02
1
OFF
Electric lock output disabled.
S
ON
Electric lock output enabled.
The electric lock is enabled in all the work programs of the door.
F03
1
Function enabled
if F02 = ON
OFF
Pulse operation for electric lock or electric striker.
Refer to the paragraph "Applications with electric lock"
S
ON
Permanent operation for electromagnet.
Refer to the paragraph "Applications with electric lock"
F04
OFF*
The electric lock output is enabled in all work programs.
S
ON
The electric lock output is enabled only in the work program "night lock"
F05
Function enabled
if F03 = OFF
OFF*
Electric lock release disabled in the work program "manual free door"
S
ON
Electric lock release enabled on each closing in the work program " manual free door"
F06
Function enabled
if F01 = OFF
OFF*
Operating mode of manual program selector in position II = selection of the work program
"night lock"
ON
Operating mode of manual program selector in position II = selection of the work program
"open door"
F07
1
OFF*
Battery module not installed
S
ON
Battery module NB-BAT installed
F08
OFF*
Operation with battery: in the absence of mains power supply, the door continues to operate
normally
ON
Operation with battery: in the absence of mains power supply, the door opens and remains
open in the automatic work programs
F09
OFF*
Operation without mains power supply with battery low: the door operates normally
ON
Operation without mains power supply with battery low: the door opens and stays open
F10
OFF*
Battery monitoring: if the battery is low or damaged, the control unit buzzer beeps before
opening for 10 cycles
ON
Battery monitoring: if the battery is low or damaged, the door opens and stays open in
automatic programs
F11
1
OFF
Closing safety sensor input disabled; when the safety sensor is not installed on the E.C. input
S
ON
Closing safety sensor input enabled; closing safety sensor on E.C. input installed.
F12
1
OFF
Opening safety sensor input disabled; when the safety sensor is not installed on the E.O.
input
S
ON
Opening safety sensor input enabled; opening safety sensor on E.O. input installed
F13
1
Function enabled
if F11 = ON
OFF
Tests on closing safety sensor E.C. disabled; for sensors which are not pre-arranged for
monitoring
S
ON
Test on closing safety sensors E.C. enabled; for sensors pre-arranged for monitoring by the
automation (cat.2/pl.c). For details, refer to the paragraph "Safety sensors".