user manual
Flashline
Flashline User Manual
page 37
Two sturdy metal handles are fitted to the front panel. The handles should be used when carrying the device, and
when fitting it in or removing it from a rack. Ensure that any door or removable rack front cover has sufficient depth
to clear the handles.
10.1.2 Dust Filters
Two dust filters are fitted behind metal covers. To remove the covers, loosen the thumbscrews located behind the
handles. Once detached, the dust filter elements can be removed for cleaning.
NEVER operate this device without the dust filters in
place.
10.1.3 Display
The display illuminates when the device is on. The LCD, function buttons, and the rotary encoder provide real-
time control and monitoring of most parameters. The LEDs embedded in the function buttons indicate available
menu options, provide confirmation of Controller communication, and indicate various faults and warnings. The
brightness and contrast of the display and front panel LEDs can be adjusted via the front panel menu.
10.1.4 Standby
The 20000DP is powered on and to standby using the top-left button, or via the Lake Controller.
10.1.5 Mute Enable
Select MUTE ENABLE to allow the dynamic function buttons to operate as mute controls for the Module inputs and
power output channels. The MUTE ENABLE button flashes when the mode is selected; a subsequent press deselects
this mode. If left activated, MUTE ENABLE mode will automatically disable two minutes after the last mute action.
10.1.6 Meter
The METER button scrolls through four alternative meter views: Home View, Module View, Temperature View and
Input View. Pressing METER from Menu Mode returns the screen to Meter Mode with Home View displayed.
10.1.7 Menu
After pressing the MENU button, the LCD will display the top level menu. In Menu Mode the function buttons enable
access to various information and functions.
10.1.8 Dynamic Function Buttons with LEDs (Left of LCD)
The function of these buttons change according to the currently selected view or menu.
• In Menu Mode they are set for menu navigation and for parameter selection
• In Meter Mode they provide Module input mute/unmute functionality in conjunction with MUTE ENABLE
The LED in the top button provides Frame fault and warning indications. The middle two buttons provide Module
input mute functionality, mute indication and faults and warning indications relating to the 20000DP inputs. The
bottom button is used only in Menu Mode or to lock the front panel buttons.