In-rush current is controlled and limited during the
soft-start sequence. This enables multiple amplifiers
on the same AC mains circuit to be turned on
simultaneously.
9.6 Grounding
Analog inputs feature Iso-Float™ ground isolation, a technology which combines the benefits of transformer-
coupled isolation with the advantages of clean, direct-coupled inputs. The audio converters are galvanically isolated,
and not connected to the main ground. High-speed transformers and opto-isolators create a barrier between the
device and the outside electrical environment.
The Iso-Float feature is activated by default, but may
be disabled via the Lake Controller software, or via
the front panel menu.
Use correctly-shielded balanced audio input connections to minimise hum and interference. NEVER disconnect the
earth (ground) pin on the mains cable (AC power cord).
10. Product Overview
10.1 Front Panel Overview
Figure 4: Front Panel Overview
The front panel controls are clustered around a daylight readable LCD, allowing adjustment and monitoring of
the majority parameters and meters. The two clusters of controls on either side of the LCD include five dedicated
function buttons, eight dynamic function buttons with embedded LEDs and a rotary data encoder .
10.1.1 Handles