32

ENGLISH

Screw on the new nozzle (56), and position the primary air adjusting ring nut (55 - Fig. C) according to the 
indications of Table 1, using a gauge or equivalent instrument to set the distance “L”, and tighten the screw 
provided to fasten the nozzle.
Turn the main switch (1) to position 1, so as to connect a single heating element (50% of the boiler’s electric 
power for single-phase heating element with 2 elements and 1/3 of power for heating elements with 3 ele-
ments with three-phase connection), and ignite the burner as in the procedure described above. When the 
water contained in the boiler reaches the preset temperature, the gas flow regulator will automatically decre-
ase the flow to the value corresponding to the reduced rated heat flow.
At this point, turn the flow regulation screw (58) so as to have a steady flame licking the sensitive thermocou-
ple element (52), and turn the screw (57) to obtain the maximum desired pressure value in the boiler.
After having verified the proper operation, replace the settings tag on the appliance with the one for the new 
type of gas that is provided with the standard kit containing the newly installed gas nozzle.
Safety devices on appliance (manually reset).

The appliance is provided with two safety devices that shut off the gas flow if the flame accidentally goes out.

1  -  Termocouple (52)

: The thermocouple operates on the valve (51), whose probe (52) must be licked by 

the flame from the burner (50). If the probe is not enveloped by the flame, the gas flow will be automa-
tically shut off.

2  -  Thermostat (59)

: The thermostat, placed in contact with the boiler, operates on the valve (51); when the 

thermostat sensor on the boiler reads 140˚C, the gas flow will be automatically shut off.

The burner can be re-ignited with the procedure described above only after the boiler body has cooled to 
110˚C. Following the activation of one of the two safety devices, try re-igniting the burner with the procedure 
already described.

 

*GUIFNBMGVODUJPOQFSTJTUTBOEUIFCVSOFSDPOTFRVFOUMZDPOUJOVFTUPHPPGGDPOUBDUUIFOFBSFTU
BVUIPSJ[FE4FSWJDFPVUMFUXIJDIXJMMQSPWJEFUPFMJNJOBUFUIFDBVTFPGUIFNBMGVODUJPO

8. Information for users in the European community

Pursuant to European Directive 2002/96/EC on electrical waste (WEEE), users in the Euro-
pean community are advised of the following.

The symbol with the crossed-out dustbin on the appliance or its packaging indicates that at 
the end of the product’s life cycle, it must be collected separately from other waste.

Suitable separate collection of the equipment for subsequent recycling, treatment and di-
sposal contributes to preventing possible negative consequences for the environment and 

health, and favours the recycling of materials that the unit is made of. 

In accordance with European Directive 2002/96/EC, abusive disposal of the product by the user will result in 
application of penalties as set forth by local law.

Содержание NEW 85

Страница 1: ...S 85 S E DE BEDIENUNG UND WARTUNGSANLEITUNG SERIE 85 S E ES MODO DE EMPLEOY MANTENIMIENTO SERIE 85 S E PT UTILIZA O E MANUTEN O S RIE 85 S E EL XPH H KAI YNTHP H EIPA 85 E MACCHINE CAFF ESPRESSO ESPRE...

Страница 2: ...19 ENGLISH OPERATION AND MAINTENANCE SERIES 85 S E...

Страница 3: ...2 Calibration of pump pressure pag 28 6 3 Calibration of water pressure in the boiler pag 28 6 4 Heating the water in the boiler pag 28 6 5 Electric cup warmer Optional pag 29 6 6 Steam delivery pag...

Страница 4: ...GJYFE BOE PS NPCJMF HVBSET SFNPWFE PS XJUI UIF TBGFUZ EFWJDFT DVU PGG 5IF TBGFUZ EFWJDFT NVTU BCTPMVUFMZ OFWFS CF SFNP WFE PS UBNQFSFE XJUI 5IF QBOFMT DPWFSJOH UIF NBDIJOF NVTU OPU CF SFNPWFE BT UIF...

Страница 5: ...22 ENGLISH 12 13 14 15 16 17 18 1 2 3 4 5 6 7 8 9 10 11 2 Exploded diagrams 19 20 Mod 85 S Mod 85 E...

Страница 6: ...ever 15 Hot water spout 16 Gas burner ignition button 17 Gas burner safety button 18 Two scale pressure gauge 19 Coffee serving button 20 Visual level indicator 21 Boiler water drain tap 22 Automatic...

Страница 7: ...automatic portions can be programmed on each brewing unit r PU XBUFS BOE TUFBN delivery on all models r VUPNBUJD XBUFS MFWFM boiler is automatically refilled on all models NO OF BREWING UNITS BOILER C...

Страница 8: ...er softener rubber drain hose with steel coil for water drain 3 8 nipples for hose connection to water supply tube cleaning brush for serving units pump suction filter on request braided 600 mm stainl...

Страница 9: ...UIF NBDIJOF UP UIF QPXFS TVQQMZ NBLF TVSF UIBU UIF EBUB PO UIF SBUJOH UBH DPSSFTQPOE UP UIF BWBJMBCMF QPXFS TVQQMZ 5IF UBH JT MPDBUFE PO UIF MFGU TJEF PG UIF NBDIJOF BOE DBO CF BDDFTTFE CZ SFNPWJOH UI...

Страница 10: ...ACK BROWN YEL GREEN BLUE BLACK BROWN BLACK YEL GREEN BLUE BLACK BROWN BLACK YEL GREEN BLACK BLACK BROWN BLUE YEL GREEN BLUE BROWN YEL GREEN N L N L3 L2 L1 N L3 L2 L1 L3 L2 L1 L3 L2 L1 N L N L 1 HEATIN...

Страница 11: ...sired value by oper ating on the pump screw the pressure is increased by turning clockwise it is decreased by turning counter clockwise As shown in the following figure there are three different cases...

Страница 12: ...d during a coffee brewing cycle Button 10 can also be used to brew the desired quantity of coffee manually press this button to start brewing and presse the button a second time to stop brewing when t...

Страница 13: ...cient water from the main water system etc After 1 30 the pump motor will shut down Note If the machine shuts down as described above call your local service technician t P OPU VTF XBUFS TQSBZT TUFBN...

Страница 14: ...e is lit check through the relative hole 54 while keeping the gas knob pressed for 5 10 secon ds After this period if the flame does not remain lit repeat the ignition operation again 7 4 Changing the...

Страница 15: ...perates on the valve 51 whose probe 52 must be licked by the flame from the burner 50 If the probe is not enveloped by the flame the gas flow will be automa tically shut off 2 Thermostat 59 The thermo...

Страница 16: ...a overvoltage overcurrent or insufficient or irregular power supply 10 Declaration of conformity The manufacturer La San Marco S p A 34072 Gradisca d Isonzo GO Italy Via Padre e Figlio Venuti 10 phone...

Страница 17: ...DPOUSPM VOJU JT defective r IFDL UIF BVUPMFWFM DJSDVJU UIF NBO ual charging button and the boiler heat exchangers r 3FQMBDF XPSO PS EBNBHFE QBSUT UP eliminate the leak r Check the wiring that feeds th...

Страница 18: ...filter on unit clogged e Filter holes widened filter cup r 4QSJOLMFS GJMUFS PO VOJU clogged r PGGFF FYUSBDUJPO UBLFT B MPOH time due to clogged filter r PGGFF FYUSBDUJPO UPP GBTU EVF to clogged sprin...

Страница 19: ...La San Marco S p A M X GX i c f M elk iX jZX jfeqf fi q X kXcp K c 0 0 Xo 0 0 _kkg1 nnn cXjXedXiZf Zfd dX c1 e f7cXjXedXiZf Zfd...

Отзывы: