The display shows
T.ProbeUnconnect
GR1
TUTTI I LED SONO LAMPEGGIANTI
GR2
TUTTI I LED SONO LAMPEGGIANTI
GR3
TUTTI I LED SONO LAMPEGGIANTI
all tHE lEDS aRE FlaSHinG
all tHE lEDS aRE FlaSHinG
all tHE lEDS aRE FlaSHinG
The alarm disappears when the temperature returns to an acceptable value.
The alarm signal is removed by turning the appliance off.
NO PULSeS FROM VOLUMeTRIC MeTeR (5 SeCONDS)
When the display shows
Alarm
Flow Meter Gr.X
this means no pulses are arriving from the volumetric meter corresponding to the activated unit (x).
Indeed, after starting up every volumetric dose (eVx + PUMP both in dispensing and in programming mode),
the dosage function checks the correct functioning of the volumetric meter by detecting the pulses it has sent
to the micro-controller.
If no pulses are detected for more than 5 seconds consecutively, the LeD relating to the selected dose begins
to flash (½ ON ½ OFF).
After 1 minute (volumetric meter time-out) of no pulses from the volumetric meter, the dose in progress stops
automatically.
FILTeR ALARM AND ReSeTTING
This function makes it possible to reset the counting of dispensing when the display shows...
ChangeWaterFilt
xxxxxxxxx
where xxx is the telephone number set as a suggestion
…this means that the value of the litres which can be cleaned by the filter set in the TeChNICAL LeVeL Pro
-
gramming has been exceeded
To reset this signal, simply power the dosage by pressing the
K3GR1
and
K4GR1
keys simultaneously.
Содержание NEW 105 T 2
Страница 2: ...italiano italiano USO E MANUTENZIONE SERIE NEW 105 TOUCH Istruzioni Originali ...
Страница 44: ...English 43 USE AND MAINTENANCE NEW 105 TOUCH SERIES Translation of the original instructions ...
Страница 86: ...Français 85 EMPLOI ET ENTRETIEN SÉRIE NEW 105 TOUCH Traduction de la version originale du mode d emploi ...
Страница 128: ...deutsch 127 BEDIENUNG UND WARTUNG SERIE NEW 105 TOUCH Übersetzung der Original Anweisungen ...
Страница 171: ......