Impeller
SHAFT LOCK
IMPELLER
The impeller must be cleaned only by
skilled technical personnel, after discon-
necting the appliance from the power
supply, according to the following
instructions:
•
Remove the tamper window by loosen-
ing the screws;
•
Press and hold upward the shaft lock
to prevent the shaft from turning;
•
With your thumb and forefinger, press
against the impeller flats. Turn the
impeller clockwise, as viewed from
below, to remove;
•
With the impeller out, clean around the
bayonet ring with a clean brush or
cloth and wipe loose grounds from this
area;
•
Insert the cleaning brush into the
coffee collection area above the
impeller and again wipe loose grounds
away;
•
Clean the impeller with a soft, dry
cloth;
•
Reinstall the impeller by turning
counter clockwise;
•
Before reconnecting the appliance to
the power supply, fix the tamper
window in correct position by relevant
screws.
Coffee outlet chute
The cleaning of the coffee outlet chute
must be made by the insertion of the
tool 5.372.5 into the hole (caution
when moving the tool).
12
EN
Produced by:
Mazzer Luigi srl
Via Moglianese,113 – 30030 Gardigiano di Scorzè (Venezia) - Italy
E-mail:[email protected] - http://www.mazzer.com
All right reserved. It is prohibited to reproduce, adapt or translate this document without prior written authorization.
First Edition:
2013
Last Revised: VS03 02/2015
Содержание vulcano swift
Страница 1: ...v u l c a n o s w i f t...
Страница 63: ...1 2 VULCANO SWIFT 3 4 2...
Страница 64: ...5 3...
Страница 65: ...6 7 80 100cm EEC 9 14 4...
Страница 66: ...8 I 5...
Страница 67: ...6...
Страница 68: ...360 1 7...
Страница 69: ...9 1kg 35s ON 45s OFF 35 45 10 8...
Страница 70: ...11 9...
Страница 72: ...14 11...
Страница 74: ......