background image

13

EN

N.B.

The programs for the first group from the 

left will become the default programs for 

the remaining groups, although you may 

wish to program these groups differently 

in  which  case  you  need  to  follow  steps 

1  to  5  for  the  remaining  control  panels. 

The  leftmost  control  panel  must  be 

programmed first; indeed, if you were to 

program  this  last,  all  its  settings  would 

be automatically transferred to the other 

groups.

It  is  recommended  that  each  group  be 

programmed separately, from left to right.

Each  button  also  works  as  a  switch  and, 

therefore,  you  may  stop  coffee  brewing 

at any time, whenever you have obtained 

the desired quantity, by pressing the same 

button.

Fault warnings

If  the  wheel  does  not  send  any  signals 

to  the  electronic  module  for  more  than 

3-4 seconds, the LED of the button which

has been pressed will start flashing. This

means that:

A) water  is  not  flowing  over  the  wheel

and  is  therefore  not  reaching  the  coffee

groups, which may be due to:

1. the  ground  coffee  being  too  fine

meaning  that  the  coffee  gets  brewed

too  slowly  (drop  by  drop)  and  therefore

the  wheel  cannot  measure  the  water

flow  within  the  factory-set  time  of  the 

electronic module.

2. insufficient  water  flow  through  the

groups  (i.e.  onto  the  coffee  powder)

probably due to a combination of one or

more of the following occurrences:

• partial blockage in one of the pipes;

• a malfunctioning motor pump;

• a malfunctioning solenoid valve;

• partial blockage of the diffuser screen.

B) there  are  calcium  deposits  inside  the

water  flow  counter  which  prevent  the

wheel from turning properly.

C) the  wheel  itself  and  the  sensor  (top

part) of the counter, may be faulty.

Coffee brewing

Take a portafilter and place some ground 

coffee  in  the  filter  itself:  1  dose  for  the 

small  filter,  2  doses  for  the  larger  filter. 

Press  down  on  the  ground  coffee  with 

the supplied tamper and engage the filter 

holder again into the bottom of the group 

and  then  press  one  of  the  buttons  with 

the symbols for 1 or 2 cups, short or long

You  may  press  the  same  button  again  in 

order to terminate coffee brewing before 

its  programmed  stop.  If  you  need  an 

unusual  amount  of  coffee,  you  may  use 

the  button  with  the  spiral  symbol  and 

press it again once you have obtained the 

desired quantity.

Once  the  coffee  has  been  completely 

brewed, the pressure in  the filter holder 

is discharged automatically, the portafilter 

may  then  be  removed  to  repeat  the 

operation as needed.

Содержание Linea

Страница 1: ...ne the industry The Linea is the classic La Marzocco machine that has long supported and helped to develop the specialty coffee industry since the 1990s It is a heavy duty workhorse that performs reli...

Страница 2: ...39 055 849 1990 page 2 page 4 page 7 page 11 page 16 page 18 page 19 page 21 page 22 1 General Warnings and Safety Specifications 2 Definition of Available Models 3 Installation 4 Machine Operation a...

Страница 3: ...nit very carefully Make sure grounding has been done correctly as it represents a fundamental safety requirement and in case of doubt do not hesitate to have qualified personnel check such connection...

Страница 4: ...the cup warmer tray with cloths or other items 13 The machine s power supply cable must not be replaced by users as also specified on the rating plate located near the outlet of such cable on the bod...

Страница 5: ...ig 2 Front panel of PADDLE model available with 1 2 3 and 4 groups 1 Main Switch 2 Water level sight glass 3 Pressure gauge 4 Coffee groups 5 Coffee brewing control switch 6 Cup warmer switch non UL m...

Страница 6: ...3groups 5 0litres 1600or1900Watts 4groups 3 4 3 4litres 1400 1400Watts 2boilersinstalled It consists of a cylindrical tank of varying length according to the number of coffee groups which is made of s...

Страница 7: ...quantity of water for one normal espresso coffee a quantity of water for one tall coffee a quantity of water for two normal coffees a quantity of water for two tall coffees The fifth button is used t...

Страница 8: ...nsion valve 20 Group cover 21 Bleed screw 22 PID Temperature Controller 23 Switch not provided 24 Plug not provided 25 Connectors Fig 4 THE COFFEE MACHINE MUST BE PLACED IN A HORIZONTAL POSITION ON A...

Страница 9: ...ould be placed on a flat counter and must be placed in settings with the following temperatures Minimum room temperature 5 C 41 F Maximum room temperature 32 C 89 F If the machine has been temporarily...

Страница 10: ...ter pump motor power cord This is the power supply for the water pump motor The internal electronics will switch the pump motor on when needed 3 core cable with 1 5 mm2 cross section or 3 core AWG 16...

Страница 11: ...l be necessary in order to completely saturate the boiler groups assembly to remove the group cover plate part 20 Fig 4 and unscrew the small bolt part 21 called bleed screws a little way so as to all...

Страница 12: ...he first installation procedures are finished before proceeding with brewing coffee hot water and steam please follow these steps Engage the portafilters by inserting them into each group brew water t...

Страница 13: ...d valve diffuser diffuser coffee brewing spout The wheel is designed in such a way as to rotate freely when water is flowing by it sends 2 signals every complete rotation to the electronic module whic...

Страница 14: ...ater flow within the factory set time of the electronic module 2 insufficient water flow through the groups i e onto the coffee powder probably due to a combination of one or more of the following occ...

Страница 15: ...ting elements in order to bring the water contained in such boiler up to operating temperature However in this case it is necessary to adjust the expansion valve marked 19A in fig 4 in such a way that...

Страница 16: ...value or SV setting value When set ting a parameter its name or its value appears 3 SEL key Used to switch the PV display to from the SV display and select a parameter block and a parameter and regis...

Страница 17: ...e press to decrease the value by 1 Press and hold this key to decrease to desired value then wait a few seconds to automatically exit programming function For more detailed information on the potentia...

Страница 18: ...u will end up with a fresh cappuccino In order to prevent part of the liquid to be heated from being sucked back into the boiler due to a possible temporary decompression inside the boiler tank which...

Страница 19: ...drain collector Remove the drain tray grill every night pull out the water drain collector and clean it thoroughly Also inspect and clean the drain well part 19 at least twice a week and remove any l...

Страница 20: ...lve part 19A should start working by discharging a few drops of water in order to prevent such pressure from exceeding 12 bar If the pressure exceeds 12 bar you must adjust the valve by unscrewing the...

Страница 21: ...sed in advance Proceed to remove the drain well piping part 19 At this point the machine may be removed from the bar being very careful not to drop it The machine is made out of various mate rials and...

Страница 22: ...tallation otherwise warranty is voided If AV Model Check shot volumes Test flowmeter s ohm value ohm value is acceptable if greater than 1 8 K ohm and less than 2 2 K ohm If MP Model Rebuild MP valve...

Страница 23: ...EN...

Отзывы: