9
EN
water supply line and the filtration system
in order to eliminate any residual particles
which could otherwise get stuck in taps or
valves thus preventing them from working
properly. Connect the water supply
connection of the espresso machine to
the water pump outlet using one of the
supplied stainless steel braided hoses.
Then connect the water pump inlet to the
water filter/softener outlet (if present).
Note:
Make sure that water supply is
always on while the pump is operating,
otherwise air can be introduced into
the brew boiler causing an undesireable
condition and damage to the pump.
3) Electrical connections
a) Power supply cord
• This is the main power supply cable that
provides power to the entire espresso
machine. There are different types of cable
based upon the electrical requirements of
the espresso machine purchased:
→ 200/220VAC 1 Phase 3-core cable with
2.5/4/6/10mm2 cross section or AWG 12/10/8
(for UL version), secured to espresso machine
via a strain relief connector
→ 220VAC 3 Phase 4-core cable with 4 mm2
cross section for versions with 1, 2 , 3 and 4
groups secured to espresso machine via a
strain relief connector
→ 380 VAC 3 Phase 5-core cable with 2.5/6
mm2 cross section for versions with 1, 2, 3 and
4 groups secured to espresso machine via a
strain relief connector.
b) Water pump motor power cord
This is the power supply for the water
pump motor. The internal electronics will
switch the pump motor on when needed.
• 3-core cable with 1.5 mm2 cross section
or 3-core AWG 16 (for UL version) secured
to espresso machine via a strain relief
connector.
4) Waste water drain connection
The espresso machine drain is to be
connected by means of the included
reinforced plastic tubing. Connect one
end of the reinforced plastic tubing to
the drain hose connection on the left side
of the espresso machine, secure with
included hose clamp.
WARNING
THE MOTOR PUMP MUST BE SITUATED CLOSE
TO THE MACHINE IN AN ACCESSIBLE PLACE
FOR MAINTENANCE BUT NOT FOR
ACCIDENTAL INTERFERENCE AND WHERE
THERE IS AN OPTIMAL AIR CIRCULATION
WARNING
- U.S.A. AND CANADA ONLY -
DO NOT CONNECT TO A CIRCUIT
OPERATING AT MORE THAN 150 V
TO GROUND
WARNING
IN ORDER TO PREVENT CRACKS OR
LEAKAGE: DO NOT STORE OR INSTALL
THE COFFEE MACHINE IN PLACES WHERE
TEMPERATURE MAY CAUSE
WATER IN BOILER OR
HYDRAULIC SYSTEM TO FREEZE.
BEFORE MAKING ANY ELECTRICAL
CONNECTIONS MAKE SURE THAT THE TWO
STRAIN RELIEF CONNECTORS ARE FIRMLY
SECURED TO THE BODY OF THE MACHINE IN
ORDER TO PREVENT INADVERTENT STRESS
ON THE POWER CABLES.
CAUTION
WARNING
THE MANUFACTURER DECLINES ANY
RESPONSIBILITY FOR ANY EVENT LEADING
TO LIABILITY SUITS WHENEVER GROUNDING
HAS NOT BEEN COMPLETED ACCORDING TO
CURRENT LOCAL, NATIONAL, AND
INTERNATIONAL REGULATIONS AND
ELECTRICAL CODES, OR OTHER ELECTRICAL
PARTS HAVE BEEN CONNECTED IMPROPERLY.
Содержание Linea