background image

EN

53

Display

Operating Procedure

Description

Programming Mode

“Barista” Programming

•  This  parameter  allows  the  operator  to 

enable/disable the coffee boiler.

•  This  parameter  allows  the  operator  to 

program  the  coffee  boiler  temperature. 
Each  group  can  have  a  different 
programming.

•  For  an  espresso  machine  composed  of 

2  and  3  groups  you  can  only  set  the 
coffee  boiler  1,  while  for  an  espresso 
machine with 4 groups you can also set 
the coffee boiler 2.

Coffee Boiler

Settings

Coffee Boiler

When  the  espresso  machine  is  turned  on,  press  and  hold  the  T3  button 

 

  to  access  the  “Barista” 

programming. After about 5 seconds the following screen is displayed. 

Move between the parameters using the buttons T1 

 

 and T2 

 

 until the display shows:

Press the T3 button 

 

 to enter the menu.

Press the T3 button 

 

 to enter the menu, move between the parameters using the buttons T1 

 

 

and T2 

 

 to select 

ENABLED

 or 

DISABLED

, press the T3 button 

 

 to confirm the option. In the 

case of option enabled you can set the following parameters.

Press the T3 button 

 

 to enter the menu, move with the buttons T1 

 

 and T2 

 

 to set the 

desired temperature, press the T3 button 

 

 to confirm the value. In the case of espresso machine a 

multiple boilers you can set the temperature also on the coffee boiler. The temperature indicated on the left 
is the actual temperature of the group while the temperature on the right is the set temperature.

LaMarzocco 00:00

CB 93.8

°

C SB

Program

Dose

Coffee Boiler

Settings

Coffee Boiler 1

ENABLED

CB1 Temperature

93.1

°

C     93.3

°

C

1

2

3

4

5

Содержание Linea PB

Страница 1: ...er 20 years ago In addition to distinctive La Marzocco features the Linea PB is equipped with exclusive user friendly interface software that gives the barista control over boiler temperature brewing volume hot water tap dose and other options ensuring a new level of performance and reliability The machine s lower profile and increased work area make it practical without abandoning world renown It...

Страница 2: ... 849 1990 page 3 page 5 page 8 page 13 page 16 page 17 page 19 page 20 page 21 page 22 Chapters 1 General Warnings and Safety Specifications 2 Definition of Available Models 3 Installation 4 Machine Operation and Coffee Preparation 5 Dispensing Steam and Hot Water 6 Maintenance and Periodic Cleaning Operations 7 De commissioning and Demolition 8 Mandatory Maintenance and Check up Operations 9 Prec...

Страница 3: ... electrical operation of this device will be achieved only when the connection to the power outlet has been completed correctly and in observance of all local national and international electrical codes and safety regulations and particularly by grounding the unit Make sure grounding has been done properly as it represents a fundamental safety requirement Ensure qualified personnel check such conn...

Страница 4: ...lation as required by local national and international electrical codes and regulations 16 In order to avoid dangerous overheating problems it is recommended that the power supply cable be fully unfurled 17 Do not obstruct air intake and exhaust grilles and in particular do not cover the cup warmer tray with cloths or other items 18 The machine s power supply cable must not be replaced by users In...

Страница 5: ... 2 Pressure Gauge Steam Brew water 3 Brew Groups 4 Control Panel 5 Group 1 Keypad 6 Digital Display 7 Steam Wand 8 Steam Knob 9 Hot Water dispense nozzle 10 Removable Drain Tray 11 Paddle Knob 12 Water Inspection Window 13 Timer 14 Precision Scale For additional information on electronics keypads and software programming please see the section entitled Software Programming your Espresso Machine 1 ...

Страница 6: ...9 bar The following table is a list of effective volumes and power ratings according to the number of groups installed 2 groups 3 4 liters 3 groups 5 liters 4 groups 6 8 liters Covers are welded at either end of the cylindrical tank and on one of them there is a housing for the water heating elements The temperature of the coffee boiler is maintained by an electronic temperature controller PID cap...

Страница 7: ...A PB 50 60 400 3N 4AV 8700 6 8 PB0000 Ifmax 20 08 12 0 9 14 5 LINEA PB 50 60 220 240 AC 4AV 8824 6 8 PB0000 38 4 08 12 0 9 14 5 ln 21 4av PB0000 08 12 33 39 161 LINEA PB 50 60 400 3N 4AV 8700 6 8 PB0000 Ifmax 20 08 12 0 9 14 5 LINEA PB 50 60 220 240 AC 4AV 8824 6 8 PB0000 38 4 08 12 0 9 14 5 ln 21 4MP PB0000 08 12 33 39 161 ...

Страница 8: ...600 4600 5040 20 22 1400 1400 1540 3000 3000 3300 4400 4400 4840 12 PER DETTAGLI 3GR 6100 6100 6690 1900 1900 2090 4000 4000 4400 5900 5900 6490 VEDERE I COLLEGAMENTI ELETTRICI 4GR 8000 8000 8780 2800 2800 3080 5000 5000 5500 7800 7800 8580 ATTENZIONE AC220 240V 60Hz AC208 240 60Hz AC400 50Hz AC220 240V 60Hz AC208 240 60Hz AC400 50Hz 23 25 29 15 30 5 33 39 20 40 THE DETAILS ON THE LEFT DESCRIBE HO...

Страница 9: ... groups 3 stainless steel braided hoses for water connections 1 5 mt of reinforced plastic tubing for drainage 1 hose clamp In order to proceed with installation it is necessary that the following are available Pipes carrying drinking water with a 3 8 G BSP end connection 3 8 Compression for USA and Canada Electrical Supply according to the specification of the espresso machine purchased Single Th...

Страница 10: ...perform a test on the water BEFORE the water treatment system and again AFTER the water system in order to verify if this is actually matching our suggested ranges Once the test has been performed learn which treatment system is most appropriate for your particular water supply by filling out the online water calculator on our website LA MARZOCCO WATER CALCULATOR http www lamarzocco com water_calc...

Страница 11: ...ef connector 380 VAC 3 Phase 5 core cable with 2 5mm2 cross section for 2 3 and 4 group versions secured to espresso machine via a strain relief connector b Water pump motor power cord This is the power supply for the water pump motor The internal electronics will switch the pump motor on when needed 3 core cable with 1 5 mm2 cross section or 3 core AWG 16 for UL version secured to espresso machin...

Страница 12: ...AME SIZE TYPE AND RAT ING F1 2A 250V WARNING U S A AND CANADA ONLY DO NOT CONNECT TO A CIRCUIT OPERATING AT MORE THAN 150V TO GROUND ON EACH LEG WARNING THE MANUFACTURER DECLINES ANY RESPONSIBILITY FOR ANY EVENT LEADING TO LIABILITY SUITS WHENEVER GROUNDING HAS NOT BEEN COMPLETED ACCORDING TO CURRENT LOCAL NATIONAL AND INTERNATIONAL REGULATIONS AND ELECTRICAL CODES OR OTHER ELECTRICAL PARTS HAVE B...

Страница 13: ...ne at a time see fig 4 to allow air to escape until water flows from below the screw head Tighten the screw to stop the water from flowing Over tightening can cause damage to the sealing washer and the group cover Repeat this procedure for all groups Once all air is removed from the coffee boiler reinstall the group cover by following the removal instructions in reverse Steam boiler Turn the main ...

Страница 14: ...em into the group and rotate the handle from left to right When the portafilters are inserted properly you can press any of brew buttons to start the flow of water through the portafilter You should allow hot water to pass through the empty portafilter s for a few seconds each time in order to pre heat the portafilter Note It is important to leave the portafilters installed in the espresso machine...

Страница 15: ...trolling the brew process using volumetric programming AV model only This espresso machine allows the volumetric programming of each of the first two buttons on each group numbered left to right Please consult the Software Programming Manual for further instructions 8 General notes for coffee preparation The portafilters must remain heated since they are at the lowest position of the group itself ...

Страница 16: ...e remember to purge the wand by opening the steam valve for a few seconds and then clean the outside of the wand itself with an appropriate cloth In order to prepare milk for making cappuccino with the right amount of foam go through the following steps After purging the steam wand place the container half full of milk underneath carefully open the steam valve and raise the container so as to brin...

Страница 17: ...s 5 Cleaning the body Wipe the stainless steel surfaces with a soft non abrasive cloth in the direction of the glazing marks if any Do not use any alcohol or solvents whatsoever on painted or imprinted parts in order not to damage them 6 Cleaning the hot water and steam nozzles Steam nozzles must be cleaned immediately after use with a damp cloth and by producing a short burst of steam so as to pr...

Страница 18: ... one minute Turn on the hot water valve for the time necessary to allow the following quantities of water to be brewed At least 1 liter for a 1 2 group machine At least 2 liters for a 3 group machine At least 3 liters for a 4 group machine If the machine is not going to be used for long periods of time it is advisable to follow these safety indications Disconnect the machine from the water mains o...

Страница 19: ... plastic tubing on the drain connection At this point the machine may be removed from the bar being very careful not to drop it or squash your fingers The machine is made out of various materials and therefore if you do not intend to put it back in service it must be taken to a special disposal company which will select the materials which can be recycled and discard the others Current regulations...

Страница 20: ... brew pressure is at 9bar Check all switches for proper operation Check note water hardness Water quality must be within the range of parameters specified in the chapter on Installation otherwise warranty is voided Check filter basket condition If AV Model Check shot volumes Test flowmeter s ohm value ohm value is acceptable if greater than 1 8 K ohm and less than 2 2 K ohm Rebuild steam assemblie...

Страница 21: ...se cleaning and maintenance Should the main grid or tray be removed ensure not to hit the load cells during the disassembly and reassembly operations To proceed with the weighing of the filter holder either empty or filled with coffee powder place it as shown below Use only original La Marzocco filters and filter holders identified by the following symbol Use only filter holders with double spout ...

Страница 22: ...own Procedures Accessing Programming Mode Cleaning Cycles Brewratio ABR version Barista Programming Program Doses available up to the 1 6 3 software version Program Doses AV and ABR versions Scales ABR version Tea Dose Coffee Boiler Pre Infusion or Pre Brewing Cup Warmer Exit Menu Technical Programming Language Temperature Measurement Units Name Program Doses available up to the 1 6 3 software ver...

Страница 23: ...he espresso machine to visibly change parameter values The display also provides valuable information to the operator There are several warnings that the can be displayed to alert the operator of an unusual condition or a fault Additionally simple messages are displayed alerting the operator that an action has been started or that a process needs to begin Digital Display LaMarzocco 09 30 94 5 94 6...

Страница 24: ...back button in the menu For simplicity s sake in this manual it will be represented by this symbol with the name T1 This button is used to control the brewing of the double espresso It is also used in the programming of the individual parameters such as the forward button in the menu For simplicity s sake in this manual it will be represented by this symbol with the name T2 This button is used for...

Страница 25: ...by this symbol with the name T1 This button is used to control the brewing of the double espresso It is also used in the programming of the individual parameters such as the forward button in the menu For simplicity s sake in this manual it will be represented by this symbol with the name T2 This button is used for a continuous control of the brewing of the espresso It is also used in the programm...

Страница 26: ...ermittent heating necessary for maintaining the temperature NOTE Ensure all air is removed from the group prior to staring the espresso machine This only needs to be completed once during the initial setup or when water is drained from the coffee boiler Instructions for bleeding the groups of air can be found in the Installation Guide HAZARDOUS VOLTAGE DISCONNECT FROM POWER SUPPLY BEFORE SERVICING...

Страница 27: ...wn to the left will be displayed The rectangles next to CB and SB indicate the warming up of the water contained in the boilers When the set temperature is reached these rectangles turn off and all the lights of the buttons turn on Now the machine is ready for use During the normal operation of the machine the flashing of the rectangles indicates the intermittent heating necessary for maintaining ...

Страница 28: ...should be blank It is important to follow this procedure when turning off the machine Failure to do so can damage the electronics The following is the procedure for turning off power to the espresso machine Please follow the procedures carefully to avoid any damage to the espresso machine This machine has two off settings One setting turns off all of the components in the espresso machine and the ...

Страница 29: ...Marzocco 00 00 CB 93 8 C SB Barista Programming Level While the espresso machine is on press and hold the button T3 After approximately 5 seconds the following display appears This is the Barista programming level To program the brewing amount for each button to set the coffee boilers the pre infusion and to enable disable the resistance of the cup warmer if present To exit the programming mode sc...

Страница 30: ...ing the rinsing process This parameter allows the operator to carry out the washing of the coffee groups in an automatic way by running multiple cleaning cycles This espresso machine has a group rinsing function rinsing jets integrated in the electronics The rinsing procedure is provided to give the operator more flexibility and freedom with regard to this operation For the MP version washing is c...

Страница 31: ...presso machine is on press and hold the button T2 After about 5 seconds the following screen is displayed When the value is no longer flashing place the empty filter holder on the appropriate seat of the grid as described in chapter 9 The value is automatically recorded Press and hold the button T1 After about 5 seconds the following screen is displayed When the value is no longer flashing place t...

Страница 32: ...ton This operation must be repeated for each button whose dose you want to set The buttons can be programmed in any sequence Press the T3 button to return to the doses programming This parameter allows the operator to program the amount of coffee brewing amount for each button on the keyboard The brewing amount can be set in terms of time sec or pulses This number refers to the number of pulses th...

Страница 33: ...meters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to program the amount of coffee brewing amount for each button on the keyboard The brewing amount can be set in terms of time sec or pulses This number refers to the number of pulses that the flowmeter sends to the CPU Once programmed the butt...

Страница 34: ...he two doses is not set or does not refer to the corresponding dose of the first group it will work as continuous dose This parameter allows the operator to program the amount of coffee brewing amount for each button on the keyboard The brewing amount can be set in terms of time sec or pulses This number refers to the number of pulses that the flowmeter sends to the CPU Once programmed the button ...

Страница 35: ...parameter allows the operator to program the amount of coffee brewing amount for each button on the keyboard The brewing amount can be set in terms of time sec or pulses This number refers to the number of pulses that the flowmeter sends to the CPU Once programmed the button remains lighted It is possible to set the dose for both a short and a long shot on the same key The setting of the first gro...

Страница 36: ... immediately press again to stop and store the desired dose To set the brewing weight of a long shot press and hold the button for about 2 seconds press and release the button immediately to store the desired dose The two doses of each key can be set independently from one another This parameter allows the operator to program the amount of coffee brewing weight for each button on the keyboard Once...

Страница 37: ... programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to program the amount of coffee brewing weight for each button on the keyboard Once programmed the button remains lighted It is possible to set the dose for both a short and a long shot on the same key It is possi...

Страница 38: ...tton to access the menu then navigate using T1 and T2 to choose between PULSES MASS and BREWRATIO This parameter allows the operator to select the coffee brewing mode among those available pulse mass and brew ratio PULSE mode control of doses in volume MASS mode control of doses in mass BREW RATIO mode ratio between the coffee powder and the weight of the drink Group Dose Settings Group Dose Setti...

Страница 39: ...other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to select the coffee brewing mode among those available pulse mass and brew ratio PULSE mode control of doses in volume MASS mode control of doses in mass BREW RATIO mode ratio between the coffee powder and the weight of the drink Gr...

Страница 40: ...e will blink Use the button T1 or T2 to change the value press the button T3 to confirm the desired value It is possible to set the value of the pulses to zero to choose a continuous dose This parameter allows the operator to view and manually change each dose for each key For greater accuracy and consistency of the doses it is recommended that you set each key The dose can be set by pulses or by ...

Страница 41: ...on T3 to exit the submenu Press the T3 button to return to the doses programming Press T1 or T2 to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to view and manually change each dose for each key For greater accuracy and consistency of the do...

Страница 42: ...e the button T1 or T2 to change the value press the button T3 to confirm the desired value Press the button T1 or T2 to view the portafilter mass of each group Pressing the button T3 the value will blink Use the button T1 or T2 to change the value press the button T3 to confirm the desired value This parameter allows the operator to view and manually change each dose for each key For greater accur...

Страница 43: ... to confirm the desired value Press the button T1 or T2 to view the dose of each key Pressing the button T3 the dose value will blink Use the button T1 or T2 to change the value press the button T3 to confirm the desired value It is possible to set the value of the mass to zero to choose a continuous dose This parameter allows the operator to view and manually change each dose for each key For gre...

Страница 44: ...ses or by mass weight G1 Dose Settings Program Dose Scales Press the button T3 to exit the submenu Press the T3 button to return to the doses programming Press T1 or T2 to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine Exit Group 1 Group Dose Exit LaMarzocco 00 00 CB 93 8 C SB ...

Страница 45: ...rocedure Press the key whose setting you want to copy Now all the keys will flash Press the key where you want to paste the previously copied setting Successful programming is indicated by the fixed lighting of the key It is possible to repeat this procedure on any key Press T1 or T2 until the display shows the exit menu press the T3 button to return to the Barista programming This parameter allow...

Страница 46: ...ameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to copy the doses present of each key to the others Copy Dose Program Dose LaMarzocco 00 00 CB 93 8 C SB 8 9 Barista Programming only on AV and ABR espresso machine models ...

Страница 47: ...o enter the doses programming procedure Press the button T1 or T2 to display the following menu Press the button T3 to confirm the procedure Now all settings are cleared Press T1 or T2 until the display shows the exit menu press the T3 button to return to the Barista programming This parameter allows the operator to cancel all the doses set Reset Volume Doses Resetting Doses Reset Volume Doses Pro...

Страница 48: ...s set Reset Volume Doses Program Dose Press T1 or T2 to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine LaMarzocco 00 00 CB 93 8 C SB 7 8 Barista Programming only on AV and ABR espresso machine models ...

Страница 49: ...is parameter is common to all groups Press the T3 button to enter the menu navigate the parameters using the buttons T1 and T2 to set the desired value This parameter is common to all groups This parameter enables the technician to set some scale parameters like Enabling disabling the offset parameter Setting the weight reading time Calibrating the scales Scales Configuration Program Scales LaMarz...

Страница 50: ... weight reading time Calibrating the scales Scales Configuration Program Scales Press the T3 button to return to the Barista programming Press T1 or T2 to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine 7 LaMarzocco 00 00 CB 93 8 C SB Barista Programming only on ABR espresso mac...

Страница 51: ...enu move between the parameters using the buttons T1 and T2 to select ENABLED or DISABLED press the T3 button T3 to confirm the option To program the brewing time press the tea button to start and then press it again to stop when the desired dose is achieved Now the saved brewing time is displayed LaMarzocco 00 00 CB 93 8 C SB Program Dose Tea Dose Settings This parameter allows the operator to pr...

Страница 52: ...ater brewing amount for the tea button This feature can be enabled or disabled Press the T3 button to return to the Barista programming Press T1 or T2 to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine LaMarzocco 00 00 CB 93 8 C SB Tea Dose Exit 6 7 8 ...

Страница 53: ...n the parameters using the buttons T1 and T2 until the display shows Press the T3 button to enter the menu Press the T3 button to enter the menu move between the parameters using the buttons T1 and T2 to select ENABLED or DISABLED press the T3 button to confirm the option In the case of option enabled you can set the following parameters Press the T3 button to enter the menu move with the buttons ...

Страница 54: ... T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine LaMarzocco 00 00 CB 93 8 C SB This parameter allows the operator to enable disable the coffee boiler This parameter allows the operator to program the coffee boiler temperature Each group can have a different programming For an espresso machine composed of 2 and 3 groups you can only set t...

Страница 55: ...o continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to program the time of pre brewing of water with the coffee Each group can have a different programming Pre brewing has only two values to be adjusted for each group The time in seconds for whic...

Страница 56: ...s using the buttons T1 and T2 until the display shows Press the T3 button to enter the menu move between the parameters using the buttons T1 and T2 to select ENABLED or DISABLED press the T3 button to confirm the option LaMarzocco 00 00 CB 93 8 C SB Program Dose Cup Warmer DISABLED This parameter allows the operator to enable or disable the cups heating function This function is displayed only on ...

Страница 57: ...mal use of the espresso machine Alternatively you can exit the Barista programming and return to the normal use of the espresso machine by pressing T2 and T3 at the same time This parameter allows the operator to exit the Barista programming and return to the normal use of the espresso machine Exit Menu Exit Menu Exit Menu LaMarzocco 00 00 CB 93 8 C SB 1 2 ...

Страница 58: ... T3 button to confirm the option Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu and return to the normal use of the espresso machine Alternatively you can exit the Technical programming and return to the normal use of the espresso m...

Страница 59: ...with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu and return to the normal use of the espresso machine Alternatively you can exit the Technical programming and return to the normal use of the espresso machine by pressing T2 and T3 at the same time Enter Password...

Страница 60: ...ue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu and return to the normal use of the espresso machine Alternatively you can exit the Technical programming and return to the normal use of the espresso machine by pressing T2 and T3 at the same time Enter Passw...

Страница 61: ...ed Successful programming is indicated by the lighting of the button This operation must be repeated for each button whose dose you want to set The buttons can be programmed in any sequence Press the T3 button to return to the doses programming This parameter allows the operator to program the amount of coffee brewing amount for each button on the keyboard The brewing amount can be set in terms of...

Страница 62: ... mode and return to the normal use of the espresso machine This parameter allows the operator to program the amount of coffee brewing amount for each button on the keyboard The brewing amount can be set in terms of time sec or pulses This number refers to the number of pulses that the flowmeter sends to the CPU Once programmed the button remains lighted Group Dose Settings Group Dose Exit Program ...

Страница 63: ... can be set independently from one another If one of the two doses is not set or does not refer to the corresponding dose of the first group it will work as continuous dose This parameter allows the operator to program the amount of coffee brewing amount for each button on the keyboard The brewing amount can be set in terms of time sec or pulses This number refers to the number of pulses that the ...

Страница 64: ...rewing amount for each button on the keyboard The brewing amount can be set in terms of time sec or pulses This number refers to the number of pulses that the flowmeter sends to the CPU Once programmed the button remains lighted It is possible to set the dose for both a short and a long shot on the same key The setting of the first group is automatically copied to the subsequent groups It is possi...

Страница 65: ...on immediately press again to stop and store the desired dose To set the brewing weight of a long shot press and hold the button for about 2 seconds press and release the button immediately to store the desired dose The two doses of each key can be set independently from one another This parameter allows the operator to program the amount of coffee brewing weight for each button on the keyboard On...

Страница 66: ...the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to program the amount of coffee brewing weight for each button on the keyboard Once programmed the button remains lighted It is possible to set the dose for both a short and a long shot on the same key It is possible to copy the doses of any key to the others Group Dos...

Страница 67: ...T2 to display the following menu Press the T3 button to access the menu then navigate using T1 and T2 to choose between PULSES MASS and BREWRATIO This parameter allows the operator to select the coffee brewing mode among those available pulse mass and brew ratio PULSE mode control of doses in volume MASS mode control of doses in mass BREW RATIO mode ratio between the coffee powder and the weight o...

Страница 68: ...t the programming mode and return to the normal use of the espresso machine This parameter allows the operator to select the coffee brewing mode among those available pulse mass and brew ratio PULSE mode control of doses in volume MASS mode control of doses in mass BREW RATIO mode ratio between the coffee powder and the weight of the drink Group Dose Settings Exit Group 1 LaMarzocco 00 00 CB 93 8 ...

Страница 69: ...the dose value will blink Use the button T1 or T2 to change the value press the button T3 to confirm the desired value It is possible to set the value of the pulses to zero to choose a continuous dose This parameter allows the operator to view and manually change each dose for each key For greater accuracy and consistency of the doses it is recommended that you set each key G1 Dose Settings Progra...

Страница 70: ... exit menu press the T3 button to return to the Technical programming Press T1 or T2 to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to view and manually change each dose for each key For greater accuracy and consistency of the doses it is r...

Страница 71: ...on T1 or T2 to change the value press the button T3 to confirm the desired value Press the button T1 or T2 to view the portafilter mass of each group Pressing the button T3 the value will blink Use the button T1 or T2 to change the value press the button T3 to confirm the desired value This parameter allows the operator to view and manually change each dose for each key For greater accuracy and co...

Страница 72: ...n T1 or T2 to view the coffee mass of each group Pressing the button T3 the value will blink Use the button T1 or T2 to change the value press the button T3 to confirm the desired value Press the button T1 or T2 to view the dose of each key Pressing the button T3 the dose value will blink Use the button T1 or T2 to change the value press the button T3 to confirm the desired value It is possible to...

Страница 73: ...tinue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine Exit Group 1 Group Dose Exit LaMarzocco 00 00 CB 93 8 C SB 11 12 10 9 This parameter allows the operator to view and manually change each dose for each key For greater accuracy and consistency of the doses it is recommended that you s...

Страница 74: ... flash Press the key where you want to paste the previously copied setting Successful programming is indicated by the fixed lighting of the key It is possible to repeat this procedure on any key Press T1 or T2 until the display shows the exit menu press the T3 button to return to the Technical programming This parameter allows the operator to copy the doses present of each key to the others Copy D...

Страница 75: ...meters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to copy the doses present of each key to the others Copy Dose Program Dose LaMarzocco 00 00 CB 93 8 C SB 8 9 only on AV and ABR espresso machine models Technical Programming ...

Страница 76: ...y the following menu Press the button T3 to confirm the procedure Now all settings are cleared Press T1 or T2 until the display shows the exit menu press the T3 button to return to the Technical programming This parameter allows the operator to cancel all the doses set Reset Volume Doses Resetting Doses Reset Volume Doses Program Dose Program Volume Dose Group Dose Settings LaMarzocco 00 00 CB 93 ...

Страница 77: ...amming This parameter allows the operator to cancel all the doses set Reset Volume Doses Program Dose Press T1 or T2 to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine LaMarzocco 00 00 CB 93 8 C SB 7 8 ...

Страница 78: ...rs using the buttons T1 and T2 to set the desired value This parameter is common to all groups This parameter indicates that the scale is properly connected navigate using the T1 and T2 buttons to display the next menu This parameter enables the technician to set some scale parameters like Enabling disabling the offset parameter Setting the weight reading time Calibrating the scales Updating the s...

Страница 79: ...o proceed with setting and press the T3 button to update the scale firmware if necessary To exit the submenu move between the parameters using the buttons T1 and T2 until the exit submenu is displayed Press the T3 button to exit the submenu Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit...

Страница 80: ...elect ENABLED or DISABLED press the T3 button to confirm the option To program the brewing time press the tea button to start and then press it again to stop when the desired dose is achieved Now the saved brewing time is displayed Enter Password This parameter allows the operator to program the amount of water brewing amount for the tea button This feature can be enabled or disabled Tea Dose ENAB...

Страница 81: ...hnical programming Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu and return to the normal use of the espresso machine Alternatively you can exit the Technical programming and return to the normal use of the espresso machine by pres...

Страница 82: ...of the group while the temperature on the right is the set temperature Coffee Boiler Settings Coffee Boiler 1 ENABLED Enter Password CB1 Temperature 93 1 C 93 3 C THE STEAM BOILER CONTAINS WATER AT ELEVATED TEMPERATURES WATER TEMPERATURE OVER 52 c CAN CAUSE SEVERE BURNS INSTANTLY OR DEATH FROM SCALDING DANGER This parameter enables the technician to set various parameters of the coffee boiler The ...

Страница 83: ...l use of the espresso machine by pressing T2 and T3 at the same time Coffee Boiler Settings Coffee Boiler CB1 Offset 3 0 C The OFFSET parameter is used to calibrate the coffee boiler temperature system to ensure the display temperature accurately represents the temperature of the water exiting the group head This parameter is preset at the factory based upon initial tests of this espresso machine ...

Страница 84: ... filling time press the T3 button to confirm the value This parameter enables the technician to set various parameters of the steam boiler The temperature of saturated water is proportional to the pressure inside the Steam Boiler Therefore it is possible to regulate the pressure of the steam boiler by means of electronic temperature control Please use the following tables as reference when setting...

Страница 85: ...menu is displayed Press the T3 button to exit the submenu Steam Boiler Settings Fill With Pump WITH PUMP Autofill Timeout 10 min SB Settings Exit The parameter filling WITH PUMP allows the technician to select the activation of the water pump during the automatic filling cycle of the service boiler Only under unusual circumstances would the option of WITHOUT PUMP be chosen The electronics installe...

Страница 86: ...arameter filling WITH PUMP allows the technician to select the activation of the water pump during the automatic filling cycle of the service boiler Only under unusual circumstances would the option of WITHOUT PUMP be chosen The electronics installed in this es presso machine give priority to the brew boiler for pressure The activation of the auto fill cycle during the brewing process can reduce t...

Страница 87: ...r LOW press the T3 button to confirm the option To exit the submenu move between the parameters using the buttons T1 and T2 until the exit submenu is displayed Press the T3 button to exit the submenu Steam Boiler Settings SB Settings Exit The parameter Level Sensit allows the technician to select the probe sensitivity for steam boiler filling according to water hardness The probe level installed c...

Страница 88: ...to the 0 position Now it is possible to turn on again the espresso machine set the main switch to position 1 and press any button to complete machine switch on Steam Boiler Exit Menu LaMarzocco 00 00 CB 93 8 C SB Steam Boiler Settings The parameter Level Sensit allows the technician to select the probe sensitivity for steam boiler filling according to water hardness The probe level installed corre...

Страница 89: ...rm the option To exit the submenu move between the parameters using the buttons T1 and T2 until the exit submenu is displayed Press the T3 button to exit the submenu Steam Boiler Settings SB Settings Exit The parameter Level Sensit allows the technician to select the probe sensitivity for steam boiler filling according to water hardness The black connection cable corresponds to the working level p...

Страница 90: ...le to turn on again the espresso machine set the main switch to position 1 and press any button to complete machine switch on Steam Boiler Exit Menu LaMarzocco 00 00 CB 93 8 C SB Steam Boiler Settings The parameter Level Sensit allows the technician to select the probe sensitivity for steam boiler filling according to water hardness The black connection cable corresponds to the working level probe...

Страница 91: ...to continue with the programming of the other parameters Press T2 and T3 at the same time to exit the programming mode and return to the normal use of the espresso machine This parameter allows the operator to program the time of pre brewing of water with the coffee Each group can have a different programming Pre brewing has only two values to be adjusted for each group The time in seconds for whi...

Страница 92: ...layed Press the T3 button to enter the menu move between the parameters using the buttons T1 and T2 to select an option NO TIME DOSE press the T3 button to confirm the option In the case of active option TIME or DOSE the display shown to the side appears Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 ...

Страница 93: ...ove between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu Alternatively you can exit the Technical programming and return to the normal use of the espresso machine by pressing T2 and T3 at the same time This parameter allows the user to set the time of day and the day of the week This parameter is used to display time and is also u...

Страница 94: ...following screen is displayed Press the T3 button to enter the menu Press the T3 button to enter the menu move between the parameters using the buttons T1 and T2 to select ENABLED or DISABLED press the T3 button to confirm the option Press the T3 button to enter the menu move between the parameters using the buttons T1 and T2 to select TIME or BY BUTTON press the T3 button to confirm the option Pr...

Страница 95: ...isplayed only on the models of espresso machine equipped with this accessory To exit the submenu move between the parameters using the buttons T1 and T2 until the exit submenu is displayed Press the T3 button to exit the submenu Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is dis...

Страница 96: ... T2 to set the desired time press the T3 button to confirm the value Press the T3 button to enter the menu move with the buttons T1 and T2 to set the desired time press the T3 button to confirm the value Press the T3 button to enter the menu move with the buttons T1 and T2 to select an option press the T3 button to confirm the option This parameter allows the technician to program the espresso mac...

Страница 97: ...ameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu Alternatively you can exit the Technical programming and return to the normal use of the espresso machine by pressing T2 and T3 at the same time This parameter allows the technician to program the espresso machine to turn on at a preset time and turn off at a preset time This feature also allo...

Страница 98: ...wing screen is displayed Press the T3 button to enter the menu Press the T3 button to enter the menu move between the parameters with the buttons T1 and T2 to set the desired temperature press the T3 button to confirm the value Press the T3 button to enter the menu move between the parameters with the buttons T1 and T2 to set the desired time in minutes press the T3 button to confirm the value A v...

Страница 99: ...also during the normal operation of the machine by pressing T1 and T2 at the same time Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu Alternatively you can exit the Technical programming and return to the normal use of the espresso ...

Страница 100: ...ttons T1 and T2 you can display the total doses of each button Continuing to move with the buttons T1 and T2 you can display the total doses of each button Continuing to move with the buttons T1 and T2 you can also display the total doses of the tea button This parameter allows the technician to review the total doses dispensed for each button This parameter displays different values Total coffee ...

Страница 101: ...Counter To exit the submenu move between the parameters using the buttons T1 and T2 until the exit submenu is displayed Press the T3 button to exit the submenu Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu Alternatively you can exi...

Страница 102: ...ion Continuing to move with the buttons T1 and T2 you can display the total doses of each group Continuing to move with the buttons T1 and T2 you can also display the total doses of the tea button This parameter allows the technician to review the total doses This parameter displays different values Total coffee doses Coffee doses for each group Tea doses Coffee Dose Counter Coffee Dose Counter Co...

Страница 103: ...e submenu move between the parameters using the buttons T1 and T2 until the exit submenu is displayed Press the T3 button to exit the submenu Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu Alternatively you can exit the Technical pr...

Страница 104: ...d Press the T3 button to enter the menu move between the parameters using the buttons T1 and T2 to select ENABLED or DISABLED press the T3 button to confirm the option Press the T3 button to enter the menu move between the parameters using the buttons T1 and T2 to select LITRES or DAYS press the T3 button to confirm the option Press the T3 button to enter the menu move between the parameters with ...

Страница 105: ...er parameters To exit the menu move between the parameters using the buttons T1 and T2 until the exit menu is displayed Press the T3 button to exit the menu Alternatively you can exit the Technical programming and return to the normal use of the espresso machine by pressing T2 and T3 at the same time Filter Alarm Exit Exit Menu This parameter allows the technician to preprogram an alarm that notif...

Страница 106: ...settings you made in the Barista programming Press the T3 button to reset the settings you made in the Technical programming To exit the submenu move between the parameters using the buttons T1 and T2 until the exit submenu is displayed Press the T3 button to exit the submenu Press T1 or T2 to continue with the programming of the other parameters To exit the menu move between the parameters using ...

Страница 107: ...chnical programming menu and entering the password use the buttons T1 and T2 until the following screen is displayed Press the T3 button to update the firmware The following screen will immediately appear Insert the USB Pendrive into the USB port and press the T3 button When the update is over the espresso machine restarts Set the switch to 0 zero and then again to 1 Update Firmware Enter Password...

Страница 108: ... Programming This parameter allows the technician to exit the Technical programming and return to the normal use of the espresso machine Exit Menu Exit Menu Press the T3 button to exit the Technical programming and return to the normal use of the espresso machine Exit Menu 1 ...

Страница 109: ...roups Bled This message is displayed during first installation and when preset of settings is made Push enter if groups have been blend ie no air is present in groups Coffee Boiler 1 Is Not Heating This message is displayed when the coffee boiler does not reach the minimum temperature with the programmed time interval See the parameter Heating Timeout for more information The number on the display...

Страница 110: ...revious state Flow Meter 1 No Pulse This message is displayed when the CPU does not receive the appropriate signal from the flowmeter When the flowmeter alarm is displayed push a button to turn off the alarm This problem is a result of water not flowing through the flow meter This can be caused by the coffee packed too tightly a blockage in the tubes a malfunctioning water pump a faulty valve or a...

Страница 111: ...EN 111 ...