8.6 Outdoor Humidity High Alarm Setting

 

 
1)  Place your cursor over the outdoor humidity high alarm box and right click the mouse to open the outdoor 

humidity high alarm window 

2)  Drag the cursor over the sliding scale to set the desired outdoor humidity high or enter the humidity in the 

box provided 

3)  Click the alarm active box to set the outdoor humidity high alarm 
4)  Click the set button to confirm 
5)  The outdoor humidity high alarm is now set and will activate when the set outdoor humidity level is 

reached (for setting the outdoor humidity high alarm setting from the base station, see main instruction 
manual). 

 
 
 
 
 
 
 
 
 
 
 
 
 

Note:

  The alarm bell icon may not appear immediately on the Heavy Weather program since it may take few 

 

seconds for the program to calculate and confirm the setting 

 
 

Once the alarm is entered into the Heavy Weather program, the information will be transferred to the 

 

base station.  In some situations, the alarm icon may not appear immediately on the base station’s 

 

LCD but will appear after a short delay due the constant data communication between all the 

 

sensors, base station and the PC. 

 
 

8.7 Outdoor Humidity Low Alarm Setting

 

 
1)  Place your cursor over the outdoor humidity low alarm box and right click the mouse to open the outdoor 

humidity low alarm window 

2)  Drag the cursor over the sliding scale to set the desired indoor humidity low or enter the humidity in the 

box provided 

3)  Click the alarm active box to set the outdoor humidity low alarm 
4)  Click the set button to confirm 
5)  The outdoor humidity low alarm is now set and will activate when the set humidity level is reached (for 

setting the outdoor humidity low alarm setting from the base station, see main instruction manual). 

 

 
 
 
 
 
 
 
 
 
 
 
 

Note:

  The alarm bell icon may not appear immediately on the Heavy Weather program since it may take few 

 

seconds for the program to calculate and confirm the setting 

 
 

Once the alarm is entered into the Heavy Weather program, the information will be transferred to the 

 

base station.  In some situations, the alarm icon may not appear immediately on the base station’s 

 

LCD but will appear after a short delay due the constant data communication between all the 

 

sensors, base station and the PC. 

 
 
 

Содержание WS-2310

Страница 1: ...Heavy Weather program 6 2 Main Heavy Weather window 7 0 Basic Settings 7 1 Heavy Weather Setting Global tab 7 2 Heavy Weather Setting Units tab 7 3 Heavy Weather Setting Pressure tab 7 4 Heavy Weather...

Страница 2: ...weather values 9 1 Absolute or relative air pressure 9 2 Indoor humidity 9 3 Outdoor humidity 9 4 Indoor temperature 9 5 Outdoor temperature 9 6 Dew point 9 7 Wind chill 9 8 Wind speed 9 9 Rain count...

Страница 3: ...ith the radio controlled time all the data is displayed on the large LCD with LED back light The base station can be battery operated using 3 x AA IEC LR6 1 5V batteries or with the AC DC adapter prov...

Страница 4: ...nd will display the weather data in the appropriate boxes Note In the event the auto install did not start double click the set exe file found in the root directory of the CD ROM to start the installa...

Страница 5: ...nd times and are automatically updated when a new minimum or maximum values are reached 5 5 Indoor and Outdoor Temperature Humidity The weather data recorded by the thermo hygro sensor for outdoor dat...

Страница 6: ...a consists of pressure indoor temperature indoor humidity outdoor temperature outdoor humidity dew point wind chill wind speed wind direction total rain time and date The user can also select to recor...

Страница 7: ...station and the received data will soon be received and displayed by the Heavy Weather program 6 2 Main Heavy Weather window Below are two windows of the Heavy Weather program before and after recepti...

Страница 8: ...sers of countries that recognizes the comma or point as the decimal separator When the decimal point or comma is selected the data digits on the main Heavy Weather window and history file s will be up...

Страница 9: ...es since there must be more than one file saved in order to select a file change Creating new history files 1 Click Change History File button to open the Select History File window 2 Type in a new fi...

Страница 10: ...tory window 1 Click the change history file button to open the select history file window 2 Click the file name to highlight selection or type in the file name and click OK to confirm and return to th...

Страница 11: ...rn back to the history file window 7 5 4 Setting of interval for reading the next set of weather data from 1 minute up to 60 hours 1 Click the change settings button to open the change history setting...

Страница 12: ...ty alarm Rainfall 24 hour Rainfall 1 hour Dew point alarm Pressure alarm Wind chill alarm Wind velocity alarm Wind direction alarm Set each alarm as follows 8 1 Storm Warning alarm setting 1 Place you...

Страница 13: ...pear after a short delay due the constant data communication between all the sensors base station and the PC 8 3 Absolute or Relative Pressure Low Alarm Setting 1 Place your cursor over the absolute o...

Страница 14: ...ar after a short delay due the constant data communication between all the sensors base station and the PC 8 5 Indoor Humidity Low Alarm Setting 1 Place your cursor over the indoor humidity low alarm...

Страница 15: ...ear after a short delay due the constant data communication between all the sensors base station and the PC 8 7 Outdoor Humidity Low Alarm Setting 1 Place your cursor over the outdoor humidity low ala...

Страница 16: ...fter a short delay due the constant data communication between all the sensors base station and the PC 8 9 Indoor Temperature Low Alarm Setting 1 Place your cursor over the Indoor temperature low alar...

Страница 17: ...after a short delay due the constant data communication between all the sensors base station and the PC 8 11 Outdoor Temperature Low Alarm Setting 1 Place your cursor over the outdoor temperature low...

Страница 18: ...fter a short delay due the constant data communication between all the sensors base station and the PC 8 13 Dew Point Low Alarm Setting 1 Place your cursor over the dew point low alarm box and right c...

Страница 19: ...fter a short delay due the constant data communication between all the sensors base station and the PC 8 15 Wind Chill Low Alarm Setting 1 Place your cursor over the wind chill low alarm box and right...

Страница 20: ...fter a short delay due the constant data communication between all the sensors base station and the PC 8 17 Wind Speed Low Alarm Setting 1 Place your cursor over the wind speed low alarm box and right...

Страница 21: ...base station s LCD but will appear after a short delay due the constant data communication between all the sensors base station and the PC 8 19 Rainfall 24 Hour Alarm Setting 1 Place your cursor over...

Страница 22: ...arm icon will light up when any weather condition has been met for the weather alarm settings This notifies the user that a set weather alarm condition has been reached To cancel and prpapre the gener...

Страница 23: ...bsolute or relative air pressure Indoor and outdoor humidity Indoor and outdoor temperature Dew point Wind chill Wind speed Rainfall in past 24 hours Rainfall in the last 1 hour 9 1 Resetting the min...

Страница 24: ...ng the records on the Heavy Weather program also resets the same recorded data on the base station 9 3 Resetting the min max outdoor humidity 1 Right click the min max button to open the outdoor3 humi...

Страница 25: ...ng the records on the Heavy Weather program also resets the same recorded data on the base station 9 5 Resetting the min max outdoor temperature 1 Right click the min max button to open the outdoor te...

Страница 26: ...ng the records on the Heavy Weather program also resets the same recorded data on the base station 9 7 Resetting the min max wind chill 1 Right click the min max button to open the wind chill min max...

Страница 27: ...g the records on the Heavy Weather program also resets the same recorded data on the base station 9 9 Resetting the rain counter for the rain total 1 Right click the total rain count button to open th...

Страница 28: ...tting the records on the Heavy Weather program also resets the same recorded data on the base station 9 11 Resetting the rain counter for the rain 1 hour 1 Right click the rain count 1 hour button to...

Страница 29: ...the records on the Heavy Weather program also resets the same recorded data on the base station 9 13 Resetting the maximum record for rain in the past 1 hour 3 Right click the max button to open the r...

Страница 30: ...greater than 95 it will display 19 or 96 Resolution 1 Rain Volume Display 0 to 39 37 inch 1h and 24h rainfall 0 to 98 38 inch Total rainfall Resolution 0 01 inch Wind Speed 0 to 111 8mph Resolution 0...

Страница 31: ...objects that give radiation characteristic and thus the range Neighboring using units operating on the same frequencies may affect the receiver Poorly screened PCs may affect the receiver and reduce t...

Страница 32: ...l between sensor and receiver thick walls Find a new location for the transmitter or receiver or use cable connection between the base station and the sensors Batteries of sensors or receiver empty Fa...

Страница 33: ...ve text files and create charts on other applications 1 Using the Heavy Weather program open the History window and save the weather data from the desired history file as a text file by clicking on th...

Страница 34: ...y using a spreadsheet program like Excel 3 The text import wizard window will open Choose delimited as the separator for each data column and click the next button 4 The Heavy Weather program uses tab...

Страница 35: ...s text or numbers for each column of data The default setting General and this is usable and click the Finish button 6 The data is then imported into the Excel ready for the user to plot a graph In th...

Страница 36: ...5 25 1 30 8 Since the weather data in this example is generated with a 1 minute interval we can use a formula to generate the time column we type M3 1 24 60 in the cell M4 This means adding 1 minute w...

Страница 37: ...e able to read the weather data directly Excel will define the data with comma as text format and thus will not be suitable for graph plotting as co ordinates There are two solutions to solve this pro...

Страница 38: ...into to a new cell for example N3 type VALUE SUBSTITUTE B3 Then an Excel readable indoor temperature reading is created B Then we copy this formula to all cells in column N A set of valid indoor temp...

Страница 39: ...ting From Excel select Insert from the pull down menu then select Chart You will see the below screen Then select XY as the chart type and click next 11 The Chart Source Data window is now open then s...

Страница 40: ...om cell M3 to M62 plot a graph between 1 30 to 2 29 The history1 M 3 M 62 is now written in the box 13 Next select the weather data as Y Axis we choose the indoor temperature as Y Axis so we have the...

Страница 41: ...customize the Titles Axes Gridlines Legend Data Labels 16 Click next then select whether you want a separate sheet or a chart inside the data sheet 17 Click finish to see the chart In this chart the...

Отзывы: