Heating milk for frothy coffee (cappuccino)
1
20
3
36
12. Water level control of boiler - Filling the boiler with water through manual
Use a tall narrow jug and fill it up to about the half-way mark.
Then plunge the steam jet pipe (
1
) into the milk.
Gradually open up the steam tap (
20
) and heat the milk for a
few seconds.
When the required amount of froth has been made and the
temperature is sufficiently high, stop the flow of steam by
turning knob (
20
) the other way (towards “0”).
When the steam jet pipe (
1
) is no longer required, clean it
thoroughly with a sponge and a clean cloth.
Level control
- An automatic water levellever built in series
in all machines, maintains the prestabilised water level inside
the boiler.
Filling the boiler
- This function should be used
only
if the
electronic level control devices are not working correctly.
Press the filling button (
36
), taking care not to exceed the MAX.
level on the boiler water level indicator (
3
).
NOTE: the MAX level MUST NOT be exceeded.