STOP
#
#
#
English
17 EN
The water doses for coffee and the hot water doses can
also be set using the "SELF-SETTING' function:
Hot water measures
1 - Press the button to be programed and keep it pressed
until the desired level is reached in the cup.
During this phase the time in seconds (top right of
display
(*)
) is increased
when the key is released, the
setting reached is memorized and appears below the
programmed key.
2 - Starting from step 1, continue programing, as desired,
on all the water buttons.
STOP
Coffee measures
1 - Fill the
¿
lter-holder with the required dosage of ground
coffee and insert it in the dispenser unit.
2 -Put the cup or container under the
¿
lter-holder spouts
and press the button to be programed. Keep it pressed
until the desired level is reached in the cup or container.
During this phase, the setting for the volumetric dosage
pulses (top right of display
(*)
) is increased. When the
key is released, the setting reached is memorized and
appears under the programmed key.
3 - Starting from step 1, continue programing, as desired,
on all the coffee buttons.
press and hold the START/STOP button for at least 8
seconds or until you hear a buzzer sound that will keep
sounding throughout the programing. The menu below will
appear on the display
(*)
, showing the keys with the relative
quantities for water for the coffee.
(*)
(where present)
When
¿
nished, press the START/STOP button. The buzzer will turn off, thus con
¿
rming that the programing has been
completed.
SELF-LEARNING
water button
t: 3.5
3.5
SELF-LEARNING
Group 1
DV: 000
090
150
080
1
0
Programming measures using the “SELF-LEARNING” function