11. Programming
Coffee Boiler -
this parameter includes
the items for setting the coffee boiler
temperature; values that can be set
are 60°C to 110°C (140°F to 230°F)
with steps of 0.5°C.
Group temperature
programming with offset correction
possible (see section in pages below).
S
oftener Reg.
-
includes the resin
regeneration parameters: litres of resin
(from 0.1 l to 25 l), hardness (from 0°F to
45°F). The decreasing resin efficiency
level is also indicated.
Change water Filter
-
On reaching the
litre level set on the display a message is
displayed which prompts replacement
of the filter.
For both functions, an efficiency
percentage is displayed (Softener/
Filter), descending from 100% to 0%.
Maintenance
-
includes 4 submenus
for setting maintenance parameters:
- Max cycles -
the number of cycles
set.
- Max days -
the number of days set.
- No. cycles/days -
this is the
number of cycles and days until next
maintenance.
- Maintenance -
YES/NO.
Enables (YES) or does not enable
countdown of the cycles and days until
the next maintenance activity.
Bds -
see section “BDS Activation” in
the following pages.
Flush
-
see section “Enabling Flush
key” in the following pages.
Low Power
- YES/NO
Drying Time
- coffee disc drying time
from 0 to 5 with steps of 0.1 seconds.
Screensaver
- Possibility of program
-
ming the screensaver display time (from
30" to 20')
Standard data -
Allows loading of
standard data or reconfiguration of the
machine. In both cases the machine is
automatically restarted.
Password-
allows change of the code
for accessing technical programming.
Содержание M100 GT
Страница 2: ...I M100 1 6 11 8 9a 9 20 13 19 19 19 15 23 Turbomilk 9c Tsn 12 35 Tsb Cold Touch DX 9b Cold Touch SX 9b...
Страница 58: ...English 53 EN 14 Cup Warmer 1 2 3...
Страница 59: ...English 54 EN 15 Stainless steel front panel 1 2...
Страница 60: ...English 55 EN The back panel may be removed only after the cup warmer has been removed 16 Rear panel 1 2...
Страница 63: ...English 58 EN 19 Coffee boiler 1 4 7 9 2 3 5 6 8 10 11...
Страница 64: ...English 59 EN...
Страница 66: ...English 61 EN 21 Turbosteam control and lance 22 Junction Box 23 Safety thermostat 1 2 1 2 3 5 4...
Страница 68: ...English 63 EN FUSE BATTERY Battery Fuse CR 2032 3V CR 2032 3V...
Страница 69: ...English 64 EN 26 TURBOSTEAM on the left side...