Contact your local L.B. White dealer for replacement parts
and service or call the L.B. White Co., Inc. at 1-800-345-7200

for assistance.  Be sure that you have your heater model
number and configuration number when calling.

L.B. White Co., Inc. warrants that the component parts of its
heater are free from defects in material and workmanship,
when properly installed, operated, and maintained in
a c c o rd a n c e   w i t h   t h e   I n s t a l l a t i o n   a n d   M a i n te n a n c e
Instructions, safety guides and labels contained with each
unit.  If, within 24 months from the date of purchase by the
end user, any component is found to be defective, L.B.
W h i te   C o . ,   I n c .   w i l l   a t   i t s   o p t i o n ,   r e p a i r  
or replace the defective part or heater, with a new part or
heater, F.O.B., Onalaska, Wisconsin.  

Registering your product online with L.B.White will
automatically qualify a unit and its component parts for
warranty consideration.  If a product has not been
registered with L.B.White, a copy of the bill of sale will be
required to establish warranty qualification.  If neither is
available, the warranty period will be 24 months from date
of shipment from L B. White.  

Replacement Parts and Service

HEATER

PARTS

L.B. White Co., Inc. warrants that replacement par ts
purchased from the company and used on the appropriate
L. B. White equipment are free from defects both in material
and workmanship for 24 months from the date of purchase
by the end user. Warranty is automatic if a component is
found defective within 24 months of the date code marked
on the part.  If the defect occurs more than 24 months later
than the date code but within 24 months from the date of
purchase by the end user, a copy of a bill of sale will be
required to establish warranty qualification. 

The warranty set forth above is the exclusive warranty
provided by L.B. White, and all other warranties, including
any implied warranties or merchantability or fitness for a
particular purpose, are expressly disclaimed.  In the event
any implied warranty is not hereby effectively disclaimed
due to operation of law, such implied warranty is limited in

duration to the duration of the applicable warranty stated
above.  The remedies set forth above are the sole and
exclusive remedies available hereunder.  L.B. White will not
be liable for any incidental or consequential damages
directly or indirectly related to the sale, handling or use of
the equipment, and in any event L.B. White's liability in
connection with the equipment, including for claims based
on negligence or strict liability, is limited to the purchase
price.  

Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you.
Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above
limitation or exclusion may not apply to you.  This warranty
gives you specific legal rights, and you may also have other
rights which vary from state to state.

To register your product and ensure full warranty, go to http://www.lbwhite.com/product-registration.

Please have the serial number(s) and model(s) handy for the products you are registering.

Warranty Policy

Содержание CR035

Страница 1: ...s manual online at www lbwhite com ATTENTION ALL USERS This heater has been tested and evaluated by ETL in accordance with the requirements of Standard ANSI Z83 7 CSA 2 14 and is listed and approved a...

Страница 2: ......

Страница 3: ...property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or b...

Страница 4: ...or or the L B White Co Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserves...

Страница 5: ...IDES AND BACK 3 3 1 0 4 5 1 37 U S 6 1 83 CANADA 10 3 05 SPECIFICATIONS CR035 Model Dimensions Inches centimeters L x W x H Minimum Safe Distances From Nearest Combustible Materials Feet Meters Fuel C...

Страница 6: ...filter the odorant Propane gas odor may differ in intensity at different levels Since propane gas is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas od...

Страница 7: ...f fuel gases and heat producing products in specific applications Your local authority can advise you about these 9 Use only compressed air a soft brush or dry cloth to clean the heater and it s compo...

Страница 8: ...affect safe operation and could result in property damage or injury 7 Heaters used in the vicinity of combustible tarpaulins canvas plastics wind barriers or similar coverings shall be located at leas...

Страница 9: ...the heater s dataplate for the gas configuration of the specific heater Do not use the heater in an propane liquid withdrawal system or application If you are in doubt contact the L B White Co Inc 13...

Страница 10: ...locked position Gripping the handle while the heater is operating or after the heater has been shut down can result in burns causing injury HANDLE 9 WARNING Fire Hazard Do not operate the heater unles...

Страница 11: ...Fig 6 FIG 6 3 Keep the safety control s button depressed for about 30 seconds to allow the thermocouple to warm up On new installations it may take a short time for gas to purge out any air before the...

Страница 12: ...ssures to the appliance to make sure that the regulator is reliable 4 Check any heater wiring for corrosion frayed or cut insulation tight connections etc Repair or replace as necessary 5 Review the h...

Страница 13: ...ter has been shut down Allow the heater to cool before performing any service Failure to follow this warning will result in burns causing injury 12 Service Instructions GENERAL WARNING Fire and Explos...

Страница 14: ...ctrode check the following areas A Igniter 1 Remove the wire from the push button igniter 2 Position a screwdriver tip about 1 8 in 3 mm from igniter See Fig 9 3 Holding the screwdriver by its handle...

Страница 15: ...ual 2 Does the pressure reading agree with that given on the dataplate If so no further checking or adjustment is required Proceed to section D 3 If the pressures does not agree with that specified on...

Страница 16: ...oblems associated with these parts 2 Burner lights but will not Restriction in gas hose See remedy for same cause in Problem 1 stay lit when safety control button is released Insufficient time allowed...

Страница 17: ...llation Used to deliver a working pressure to the appliance under varying conditions in tank pressure SAFETY CONTROL VALVE A gas control valve which is held open by electrical power supplied by the th...

Страница 18: ...17 Parts Identification Parts Schematic...

Страница 19: ...ter 573315 6 Safety control valve 573250 7 Pressure tap assembly 573311 8 Burner orifice 573252 9 Thermocouple 573253 10 Thermocouple bracket 573263 11 Tip switch 573254 12 Electrode 573256 13 Electro...

Страница 20: ...nths of the date code marked on the part If the defect occurs more than 24 months later than the date code but within 24 months from the date of purchase by the end user a copy of a bill of sale will...

Страница 21: ...UTILISATEURS VEUILLEZ PRENDRE NOTE Cet appareil a t test et valu par le ETL selon les normes en vigueur ANSI Z83 7 CSA 2 14 Il est homologu et approuv titre d appareil de chauffage de construction cha...

Страница 22: ...s rieuses ou la mort MISE EN GARDE G N RALE Le non respect des mesures de pr cautions ainsi que des directives d utilisation de cet appareil telles que d crites dans ce manuel peut entrainer La mort...

Страница 23: ...de produits L B White ou avec L B White directement pour toute interrogation ou assistance au sujet de cet appareil et son fonctionnement L B White croit fermement dans le d veloppement et l am liorat...

Страница 24: ...nimales de d gagement des mati res combustibles environnantes M tres Consommation de combustible l heure kg 4 Combustible Pression au manifold du br leur kPa CR035 Dimensions cm L x W x H Sp cificatio...

Страница 25: ...lement l immeuble avant d y retourner S assurer que la fuite est colmat e et r par e par du personnel qualifi Bien s assurer que la fuite a bel et bien t colmat e et seulement alors rallumer l apparei...

Страница 26: ...fonctionne 7 Il nous est parfois ardu de pr dire les cons quences de l uitlisation de nos appareils dans certaines conditions particuli res Communiquez avec le service des incendies de votre localit...

Страница 27: ...t rieur seulement L appareil de chauffage sera s install il n est pas directement expos pour arroser le spray la pluie ou d goutter l eau 17 Un r servoir de gaz propane d une dimension minimale de 45...

Страница 28: ...une fuite v rifier la propret des pi ces en cause notamment dans le filage des joints de branchement o il pourrait y avoir quelques salet s puis appliquer nouveau de la p te isolante avant de resserer...

Страница 29: ...raccord P O L Conserver le capuchon Disposer le r gulateur comme indiqu 2 Ins rer le raccord P O L dans la valve d alimentation en gaz propane Consulter la figure 3 Serrer l crou sur le raccord dans l...

Страница 30: ...upport des roulettes pour verrouiller celles ci en place avant d allumer l appareil de chauffage Consulter la figure 4 FIG 4 Pendant les d placements seulement faire pivoter la poign e vers le haut et...

Страница 31: ...n de la valve environ 30 secondes pour permettre le r chauffement du thermocouple Il faut noter que sur des installations r centes il peut s couler quelques instants avant que le gaz ne chasse l air e...

Страница 32: ...le radiateur doivent tre d gag s et libres de toute mati re combustible d essence et d autres vapeurs et liquides inflammables 2 Le r gulateur doit tre inspect de temps autre afin d assurer que l vent...

Страница 33: ...uffage avec de l air comprim ou un chiffon doux et sec Ne pas utiliser de lime de perceuse ou autre pour nettoyer l orifice Ces outils peuvent agrandir le trou ce qui causerait des probl mes de combus...

Страница 34: ...ments suivants A Allumeur 1 Retirer le fil reli au bouton poussoir de l allumeur 2 Placer la pointe d un tournevis une distance d environ 3 mm de l allumeur Voir Fig 9 3 En tenant le tournevis par sa...

Страница 35: ...de pression coincident elles avec la fiche signal tique Si oui aucune autre v rification ou ajustements ne sont n cessaires Veuillez vous rendre directement la section D 3 Si les lectures de pression...

Страница 36: ...acer le orifice D brancher la ligne d alimentation en gaz de l appareil ou celle de la veilleuse et d bloquer l aide d air comprim ou remplacer la les ligne s Appuyer fond sur le bouton poussoir de la...

Страница 37: ...ource d alimentation principale ou d un r servoir jusqu l appareil ALLUMEUR PIEZO Composante g n rant le voltage requis l allumage lorsque le bouton de l allumeur a t press Ce voltage est dirig vers l...

Страница 38: ...Identification des pi ces composantes SCHEMA DES PIECES COMPOSANTES 18...

Страница 39: ...tation en gaz 573315 6 Valve de contr le 573250 7 Manifold 573311 8 Orifice du br leur 573252 9 Thermocouple 573253 10 Support du thermocouple 573263 11 Interrupteur de basculement 573254 12 lectrode...

Страница 40: ...v rait d fectueuse l int rieur d une p riode de 24 mois d butant la date code inscrite sur ladite pi ce Si la d fectuosit survient plus de 24 mois apr s la date code mais n anmoins l int rieur d une p...