6.1 RMS/ Frequency measurement
KEW 2062/2062BT
- 21 -
KEW 2062/2062BT
Chapter 6 Display items by measurement function
6.1 RMS/ Frequency measurement
While viewing “Waveform” on your Smartphone or tablet device using our
app via Bluetooth, KEW 2062BT’s LCD will be like the illustration shown
to the right and won’t show the measured values.
To check the measured values on the instrument, switch the item on your
Bluetooth device using the app from “Waveform” to “Measured value”, or
disconnect Bluetooth communication.
RMS current, frequency
Set the function switch to “
“.
Auto-ranging function activates and switches the current range
depending on the measured value.
A short press of Mode button: switches display modes between
Inst, MAX, MIN, AVG, and |PEAK|.
* Each of above values is determined after pressing the mode
button and measurements get started.
A long press of Mode button: clears measured values (MAX, MIN, AVG, and |PEAK|).
Instantaneous value
MAX (Max. value)
MIN (Min. value)
|PEAK| (Peak value)
AVG (Average value)
Range is fixed while the LCD is showing MAX, MIN, AVG, or |PEAK|. The auto-ranging function
is reactivated when switching the display to instantaneous value.
Mode
button
Mode
button
Mode button
Mode button
Mode
button
KEW 2062/2062BT
RMS voltage, frequency
KEW 2062/2062BT
- 22 -
Note
●
When current is measuring current in PEAK mode, opening and closing operation of the
current sensor affects the readings. To obtain accurate readings, check the readings
while clamping onto the conductor to be tested or turn on the data hold function before
unclamping the conductor.
●
In the PEAK mode, sampling is performed in one cycle and PEAK value (crest value) is
determined based on the result. The sampling is performed just once in 0.5s, therefore,
the Tester cannot measure a sudden input signal such as inrush current.
RMS voltage, frequency
Set the function switch to “
“.
A shot press of Mode button: switches display modes
between Inst, MAX, MIN, AVG, and |PEAK|.
* Each of above values is determined after pressing the mode
button and measurement get started.
A long press of Mode button: clears measured values (MAX
,
MIN
,
AVG
, and
|PEAK|).
Instantaneous value
MAX (Max. value)
MIN (Min. value)
|PEAK| (Peak value)
AVG (Average value)
Note
●
In the PEAK mode, sampling is performed in one cycle and PEAK value (crest value) is
determined based on the result. The sampling is performed just once in 0.5s, therefore,
the Tester cannot measure a sudden input signal such as inrush current.
Mode
button
Mode
button
Mode button
Mode button
Mode
button
Instantaneous value
MAX (Max. value)
MIN (Min. value)
|PEAK| (Peak value)
AVG (Average value)
Mode
button
Mode
button
Mode button
Mode button
Mode
button
www.
.com
1.800.561.8187