Chapter 3 Basic operation
KEW 2062/2062BT
- 11 -
KEW 2062/2062BT
3.3 Symbols displayed in LCD
Symbol
Details
Battery indicator: shows remaining battery in 4 levels.
Bluetooth is available. (KEW2062BT only)
LCD display update is held.
Unbalance measurement has been selected. Nothing is displayed for
balance measurement.
Wiring configuration. No indication for single-phase.
Total power: when “either “P1” or “P2” is displayed, it indicates the
power of the single-phase according to the display.
Buzzer is disabled.
Type of total harmonics distortion factor.
Harmonics order: shows 1st (h-1) fundamental wave to 30th (h-30).
VT ratio other than 1/1 has been set.
CT ratio other than 1/1 has been set.
Appears to indicate the type of measured value.
LCD displays the preset nominal frequency at harmonics measurement.
If set 50Hz, LCD displayed “50Hz”.
Negative (-) or positive (no symbol) mark is displayed according to the
polarity of a measured value. For further detail, please see “9.3
Measurement specifications”.
3.4 Unit of measured value
Unit
V
RMS voltage
A
RMS current
Hz
Frequency
kW
Active power
kVar
Reactive power
kVA
Apparent power
PF
Power factor
deg
V-A phase difference
%
Harmonics
content rate
KEW 2062/2062BT
3.4 Unit of measured value
KEW 2062/2062BT
- 12 -
Chapter 4 Getting started
4.1 Turning on KEW 2062 / 2062BT
Note
●
If the instrument is in powered-off state, though the function switch is set to any measure-
ment range, auto-power off function might be activated. Turn the function switch to OFF,
and then set the switch to the desired position to wake up the instrument.
Even though the instrument doesn’t wake up, the installed batteries may be totally
exhausted. Please replace the batteries with new ones and try again.
4.2 Battery level check
DANGER
●
Never try to replace batteries during a measurement.
WARNING
●
Before opening the battery compartment cover for battery replacement, disconnect all test
leads from the instrument and set the function switch to “OFF”.
●
Do not replace batteries if the instrument is wet.
●
Accurate measurement results cannot be obtained while the battery warning indicator
“
” is blinking. Stop using the instrument and replace the batteries with new ones
immediately. If the batteries are totally exhausted, the LCD doesn’t show anything nor
“
” symbol.
When setting the function switch to any
position other than “OFF”, KEW 2062 /
2062BT gets started and all the LCD
segments are displayed for 1 sec.
Confirm that there’re no chips of
segments.
www.