2FB/2FC-4
1-5-37
C5600
Drum surface potential problem 1
• Grid voltage at 4.5 V could not deter-
mine the potential.
• Potential adjustment in 30 times could
not raise the potential sensor value to
the predetermined.
Deteriorated main
charger.
Check the main charger wire and replace it if
necessary (see page 1-6-33).
Grid or main
charger shield is
dirty.
Clean the grid or main charger shield if nec-
essary.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation.
C5610
Drum surface potential problem 2
• Grid voltage at 0.3 V could not deter-
mine the potential.
• Potential adjustment in 30 times could
not lower the potential sensor value to
the predetermined.
Defective drum
surface potential
sensor.
Replace the drum surface potential sensor.
Defective high volt-
age PWB.
Replace the high voltage PWB and check
for correct operation.
Defective drum.
Replace the drum (see page 1-6-56).
Defective engine
PWB.
Replace the engine PWB.
C6000
Fuser heater lamp break
• The fuser temperature does not
increase for 40 s after the fuser heat-
ers have been turned on for warming
up.
• The fuser temperature remains below
50
°
C/122
°
F for 10 s continuously
after the fuser heaters have been
turned on during stabilization.
Installation defec-
tiveness on fuser
thermistor M and S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Defective fuser
thermostat.
Replace the fuser thermostat (see page 1-6-
75).
Installation defec-
tiveness on fuser
heater L, M or S.
Check the mounting state of the fuser ther-
mistor L, M and S. If any problem is found,
repair it.
Broken fuser
heater L, M and S
wire.
Check for continuity. If none, replace the
fuser heater L, M and S (see page 1-6-76).
Defective engine
PWB.
Replace the engine PWB.
Defective AC
power source
PWB.
Replace the AC power source PWB.
C6020
Fuser thermistor high-temperature
detection error
• The fuser temperature exceeds 235
°
C/455
°
F for 10 s.
• The fuser high-temperature signal is
detected for continous 500 ms.
Installation defec-
tiveness on fuser
thermistor M and S.
Check the mounting state of the fuser ther-
mistor M and S. If any problem is found,
repair it.
Defective fuser
thermistor M and
S.
Replace the fuser thermistor M and S (see
page 1-6-75).
Defective engine
PWB.
Replace the engine PWB.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Содержание KM-6030
Страница 1: ...SERVICE MANUAL Published in March 2006 842FB114 Rev 4 KM 6030 KM 8030...
Страница 4: ...This page is intentionally left blank...
Страница 10: ......
Страница 82: ...2FB 2FC 2 0 1 4 13 This page is intentionally left blank...
Страница 90: ...2FB 2FC 3 1 4 19 This page is intentionally left blank...
Страница 110: ...2FB 2FC 3 1 4 37 This page is intentionally left blank...
Страница 184: ...2FB 2FC 4 1 5 25 This page is intentionally left blank...
Страница 267: ...2FB 2FC 3 1 6 30 This page is intentionally left blank...
Страница 288: ...2FB 2FC 4 1 6 51 This page is intentionally left blank...
Страница 323: ...2FB 2FC 2 0 1 6 84 This page is intentionally left blank...
Страница 463: ......