2FB/2FC-3
1-4-64
U472
Adjusting the laser output position
Description
Adjust the writing position of a laser output.
Purpose
Enter the numerical value indicated by the LSU cover in order to arrange the writing position of three laser
when replacing the laser scanner unit.
Method
Press the start key. The screen for executing is displayed.
Setting
1. Select the item to be adjusted.
2. Change the setting using the cursor up/down keys.
3. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in the interrupt copying
mode.
Completion
Press the stop/clear key at the screen for selecting an item. The screen for selecting a maintenance item No.
is displayed.
U504
Initializing the scanner NIC
Description
Initializing the optional scanner NIC to its factory default.
Purpose
To return to a setup at the time of factory shipments.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel. It is displayed in reverse.
3. Press the start key. All data in the scanner NIC is initialized.
Completion
To exit this maintenance item without executing initialization, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U505
Setting data base assistant
Description
Sets whether or not the database linkage setting is enabled if an optional network scanner is installed.
Purpose
According to user request, changes the setting.
Method
Press the start key. The screen for selecting an item is displayed.
Setting
1. Select ON or OFF. The selected item is displayed in reverse.
Initial setting: ON
2. Press the start key. The setting is set, and the screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the current setting, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Display
Description
Setting range
Default setting
DLY 1
Delay value of PWM1 output
0 to 15
0
DLY 2
Delay value of PWM2 output
0 to 15
0
DLY 3
Delay value of PWM3 output
0 to 15
0
Display
Description
ON
Database linkage setting is enabled.
OFF
Database linkage setting is disabled.
Содержание KM-6030
Страница 1: ...SERVICE MANUAL Published in March 2006 842FB114 Rev 4 KM 6030 KM 8030...
Страница 4: ...This page is intentionally left blank...
Страница 10: ......
Страница 82: ...2FB 2FC 2 0 1 4 13 This page is intentionally left blank...
Страница 90: ...2FB 2FC 3 1 4 19 This page is intentionally left blank...
Страница 110: ...2FB 2FC 3 1 4 37 This page is intentionally left blank...
Страница 184: ...2FB 2FC 4 1 5 25 This page is intentionally left blank...
Страница 267: ...2FB 2FC 3 1 6 30 This page is intentionally left blank...
Страница 288: ...2FB 2FC 4 1 6 51 This page is intentionally left blank...
Страница 323: ...2FB 2FC 2 0 1 6 84 This page is intentionally left blank...
Страница 463: ......