2FB/2FC-3
1-4-38
U161
Supplement
While this maintenance item is being executed, the copy of whole surface black can be outputted in the inter-
rupt copying mode.
Completion
Press the stop/clear key at the screen for adjustment.
The screen for selecting a maintenance item No. is displayed.
U162
Stabilizing fuser forcibly
Description
Stops the stabilization fuser drive forcibly, regardless of fuser temperature.
Purpose
To forcibly stabilize the machine before the fuser section reaches stabilization temperature.
Method
1. Press the start key. The screen for executing is displayed.
2. Press the start key.
The forced stabilization mode is entered, and stabilization operation stops regardless of fuser tempera-
ture. The screen for selecting a maintenance item No. is displayed.
To exit the forced stabilization mode, turn the power off and on.
Completion
To exit this maintenance item without executing forced fuser stabilization, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U163
Resetting the fuser problem data
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key. The screen for executing is displayed.
2. Press EXECUTE on the touch panel.
3. Press the start key. The detection of a service call code is cleared.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
U167
Checking/clearing the fuser count
Description
Displays and clears the fuser count for checking.
Purpose
To check or clear the fuser count after replacement of the fuser unit.
Method
Press the start key. The fuser count is displayed.
Clearing
1. Press the reset key.
2. Press the start key. The count is cleared.
Setting
1. Enter a seven-digit value using the numeric keys.
2. Press the start key. The value is set. The screen for selecting a maintenance item No. is displayed.
Completion
To exit this maintenance item without changing the count, press the stop/clear key.
The screen for selecting a maintenance item No. is displayed.
U180
Checking the cleaning count
Description
Displays the cleaning count for checking.
Purpose
To check the cleaning count after replacement of the cleaning unit.
Method
Press the start key. The cleaning count is displayed.
Completion
Press the stop/clear key. The screen for selecting a maintenance item No. is displayed.
Maintenance
item No.
Description
Содержание KM-6030
Страница 1: ...SERVICE MANUAL Published in March 2006 842FB114 Rev 4 KM 6030 KM 8030...
Страница 4: ...This page is intentionally left blank...
Страница 10: ......
Страница 82: ...2FB 2FC 2 0 1 4 13 This page is intentionally left blank...
Страница 90: ...2FB 2FC 3 1 4 19 This page is intentionally left blank...
Страница 110: ...2FB 2FC 3 1 4 37 This page is intentionally left blank...
Страница 184: ...2FB 2FC 4 1 5 25 This page is intentionally left blank...
Страница 267: ...2FB 2FC 3 1 6 30 This page is intentionally left blank...
Страница 288: ...2FB 2FC 4 1 6 51 This page is intentionally left blank...
Страница 323: ...2FB 2FC 2 0 1 6 84 This page is intentionally left blank...
Страница 463: ......