2PX/2PY
1-5-29
(2) Detaching and refitting the power source PWB
Procedure
1. Remove the right rear cover, right cover
and right lower cover (see page 1-5-6).
2. Remove four screws and then remove
the power source shield.
Screws A and B are unidentical, there-
fore, do not mix up.
Figure 1-5-41
3. Remove all connectors from power
source PWB.
4. Remove two screws.
5. Release three hooks and then remove
the power source PWB.
6. Check or replace the power source
PWB and refit all the removed parts.
Figure 1-5-42
Power source shield
Screw B
Screws A
Screw A
Power source PWB
Screw
Hook
Hook
YC103 YC105
YC104
YC101
YC102
Hook
Screw
Содержание 6026
Страница 1: ...SERVICE MANUAL Published in March 2014 842PY112 2PYSM062 Rev 2 ECOSYS M6026cidn ECOSYS M6526cidn ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 134: ...2PX 2PY 1 3 96 This page is intentionally left blank ...
Страница 237: ...2PX 2PY 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit ...
Страница 275: ...2PX 2PY 1 5 89 4 Remove the paper conveying unit Figure 1 5 145 Paper conveying unit 1 2 2 ...
Страница 280: ...2PX 2PY 1 5 94 This page is intentionally left blank ...
Страница 323: ...2PX 2PY 2 2 10 This page is intentionally left blank ...
Страница 371: ...1 1 INSTALLATION GUIDE INSTALLATION GUIDE FOR Card Authentication Kit D ...
Страница 372: ...1 2 3 4 5 a a c CARD READER CARD READER HOLDER D b ...
Страница 373: ...10 b c 6 8 9 7 ...
Страница 375: ......