2PX/2PY
1-4-19
4700
VIDEO ASIC device error
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Main PWB (YC39) and relay PWB (YC3)
Relay PWB (YC2, 4) and engine PWB (YC8,
9)
Defective main
PWB or engine
PWB.
Replace the main PWB or the engine PWB
and check for correct operation (see page 1-
5-30, 1-5-27).
5301
Broken cleaning lamp K
wire
When the cleaning lamp K is
driven, the lamp over-current
detection signal is detected
continuously for 10 times (1 s)
at 100 ms intervals.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum unit K and Drum relay PWB (YC2)
Drum relay PWB (YC1) and engine PWB
(YC34)
Defective cleaning
lamp K.
Replace the drum unit K. (see page 1-5-21).
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
5302
Broken cleaning lamp C
wire
When the cleaning lamp C is
driven, the lamp over-current
detection signal is detected
continuously for 10 times (1 s)
at 100 ms intervals.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum unit C and Drum relay PWB (YC4)
Drum relay PWB (YC1) and engine PWB
(YC34)
Defective cleaning
lamp C.
Replace the drum unit C. (see page 1-5-21).
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
5303
Broken cleaning lamp M
wire
When the cleaning lamp M is
driven, the lamp over-current
detection signal is detected
continuously for 10 times (1 s)
at 100 ms intervals.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum unit M and Drum relay PWB (YC3)
Drum relay PWB (YC1) and engine PWB
(YC34)
Defective cleaning
lamp M.
Replace the drum unit M. (see page 1-5-21).
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
Code
Contents
Causes
Check procedures/
corrective measures
Содержание 6026
Страница 1: ...SERVICE MANUAL Published in March 2014 842PY112 2PYSM062 Rev 2 ECOSYS M6026cidn ECOSYS M6526cidn ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 134: ...2PX 2PY 1 3 96 This page is intentionally left blank ...
Страница 237: ...2PX 2PY 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit ...
Страница 275: ...2PX 2PY 1 5 89 4 Remove the paper conveying unit Figure 1 5 145 Paper conveying unit 1 2 2 ...
Страница 280: ...2PX 2PY 1 5 94 This page is intentionally left blank ...
Страница 323: ...2PX 2PY 2 2 10 This page is intentionally left blank ...
Страница 371: ...1 1 INSTALLATION GUIDE INSTALLATION GUIDE FOR Card Authentication Kit D ...
Страница 372: ...1 2 3 4 5 a a c CARD READER CARD READER HOLDER D b ...
Страница 373: ...10 b c 6 8 9 7 ...
Страница 375: ......