2PX/2PY
1-4-9
1030
PF lift motor error
(paper feeder 2)
When the lift motor is driven,
the motor over-current detec-
tion signal is detected continu-
ously for 50 times (5 s) at 100
ms intervals.
After the lift motor is driven,
the ON status of lift sensor
cannot be detected for 8 s.
The cassette installed confir-
mation message is displayed
on the operation panel, and
even if the cassette is opened
and closed, the cassette
installed confirmation mes-
sage is displayed 5 times suc-
cessively.
Defective bottom
plate elevation
mechanism in the
cassette.
Check to see if the bottom plate can move
smoothly and repair it if any problem is
found.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
PF lift motor and PF main PWB (YC7)
Defective drive
transmission sys-
tem of the PF lift
motor.
Check if the gears rotate smoothly. If not,
grease the bushes and gears. Check for
broken gears and replace if any.
Defective PF lift
motor.
Replace the PF lift motor
Defective PF main
PWB.
Replace the PF main PWB (Refer to the ser-
vice manual for the paper feeder).
1500
PF heater 1 high tempera-
ture error
(paper feeder 1)
A temperature higher than
75
C/167
F is detected.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
PF fan motor 1 and PF main PWB (YC111)
Shorted PF therm-
istor 1.
Replace the top heater unit (Refer to the
service manual for the paper feeder).
Defective PF fan
motor 1.
Replace the top heater unit (Refer to the
service manual for the paper feeder).
Defective PF main
PWB.
Replace the PF main PWB (Refer to the ser-
vice manual for the paper feeder).
1510
PF heater 2 high tempera-
ture error
(paper feeder 1)
A temperature higher than
75
C/167
F is detected.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
PF fan motor 2 and PF main PWB (YC111)
Shorted PF therm-
istor 2.
Replace the side heater unit (Refer to the
service manual for the paper feeder).
Defective PF fan
motor 2.
Replace the side heater unit (Refer to the
service manual for the paper feeder).
Defective PF main
PWB.
Replace the PF main PWB (Refer to the ser-
vice manual for the paper feeder).
Code
Contents
Causes
Check procedures/
corrective measures
Содержание 6026
Страница 1: ...SERVICE MANUAL Published in March 2014 842PY112 2PYSM062 Rev 2 ECOSYS M6026cidn ECOSYS M6526cidn ...
Страница 4: ...This page is intentionally left blank ...
Страница 10: ...This page is intentionally left blank ...
Страница 134: ...2PX 2PY 1 3 96 This page is intentionally left blank ...
Страница 237: ...2PX 2PY 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit ...
Страница 275: ...2PX 2PY 1 5 89 4 Remove the paper conveying unit Figure 1 5 145 Paper conveying unit 1 2 2 ...
Страница 280: ...2PX 2PY 1 5 94 This page is intentionally left blank ...
Страница 323: ...2PX 2PY 2 2 10 This page is intentionally left blank ...
Страница 371: ...1 1 INSTALLATION GUIDE INSTALLATION GUIDE FOR Card Authentication Kit D ...
Страница 372: ...1 2 3 4 5 a a c CARD READER CARD READER HOLDER D b ...
Страница 373: ...10 b c 6 8 9 7 ...
Страница 375: ......