2DC
1-6-48
(8) Adjusting the scanner center line
Perform the following adjustment if there is a regular error between the center lines of the copy image and original.
U034
(P. 1-6-42)
U072
(P. 1-6-53)
U067
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Yes
No
Start
Enter maintenance mode.
Enter “067” using the copy exposure
adjustment keys or zoom +/- keys.
Press the start key.
Press the program key and the
machine enters the test copy mode.
Place an original and press
the start key to make a test copy.
Is the scanner
center line correct?
Press the start key.
The new setting
is stored.
Setting range: –66 – +66
Initial setting: 15
Changing the value by 1 moves
the center line by 0.17 mm.
For copy example 1, increase
the value using the zoom (+) key.
For copy example 2, decrease
the value using the zoom (–) key.
Press the stop/clear key to
exit maintenance mode.
End
Original
Copy
example 1
Copy
example 2
Scanner center line
Figure 1-6-58