![Kyocera Mita KM-1500 Скачать руководство пользователя страница 118](http://html1.mh-extra.com/html/kyocera-mita/km-1500/km-1500_service-manual_2016984118.webp)
2DC
1-6-33
3. Remove two screws and then remove two grounding plates.
4. Remove the one stopper ring and then detach the scanner shaft.
* Detach the shaft taking care to tilt it as little as possible.
Figure 1-6-37 Detaching the scanner shaft
5. Remove the flexible flat cable from the ISU
board’s connector.
6. Remove the scanner belt from the belt hook
of scanner unit.
7. Remove the ISU unit from the scanner shaft.
* Remove the ISU unit taking care not to lose
the M4 nut located in the ISU unit.
Figure 1-6-38 Removing the ISU unit
Flexible flat cable
ISU board
M4 nut
ISU unit
Scanner belt
Scanner shaft
Scanner unit
Belt hook
Stopper ring
Grounding plates
Screw
Screw
Scanner shaft
Содержание KM-1500
Страница 1: ......
Страница 64: ...2DC 1 5 2 2 Paper misfeed detection conditions Registration sensor Exit sensor Figure 1 5 2...
Страница 102: ...2DC 1 6 17 15 Remove the four screws 16 Remove the drive unit Figure 1 6 19 Removing the drive unit Screws Drive unit...
Страница 116: ...2DC 1 6 31 Eraser lamp 9 Remove the eraser lamp 5 2 34 Removing the eraser lamp...