2DC
1-6-29
Screws
Screws
Screw
Connectors
Screw
LSU shield
1
3
4
2
1-6-11 Removing the laser scanner unit and the eraser lamp
1. Remove the scanner unit (See page 1-6-27).
2. Remove each two screws and then remove
two grounding plates.
3. Remove each two screws and then remove
the right and left scanner stays.
Figure 1-6-31 Removing the right and left stays
4. Remove four connectors.
5. Remove six screws and then remove the LSU
shield.
* When refitting the LSU shield, tighten a
screw in order of
4
from
1
.
Figure 1-6-32 Removing the LSU shield
Screws
Right scanner stay
Left scanner stay
Screws
Screws
Grounding plates
Содержание KM-1500