SICOM6000 User’s Manual
-26-
mode fiber ports SFP module and RJ45 ports SFP module. Fiber ports can form fiber redundant ring
network. When the failure occur in the network, the recovery time is within 50ms. The fiber ports
support LC connector.
CAUTION
:
Laser is used to transmit signals in fiber cables. Routine operation do not harm to eyes, but do not
directly look at the fiber port when the switch is powered on.
The connecting steps are as follows
1
.
Remove the rubber caps of the fiber ports and keep them for protecting the ports when they
are not used.
2
.
Check whether the ports are clean. Dirty ports might affect the transmitting quality. Use wet
handkerchiefs or cotton balls to sweep the cable connectors.
3
.
Connect the fiber cables to fiber ports
4
.
After connection, check the corresponding LINK/ACT indicator in the front panel of switch. If
the indicator goes on, it means an effective connection.
4.5
Cable
Wiring
Cable wiring should meet the following requirements:
1
.
Before cable wiring, check whether the specifications, models and quantities of all cables
comply with the construction drawing design and contract requirements.
2
.
Before cable wiring, it is necessary to check whether there are damaged cables and whether
the cables are accompanied by ex‐factory records and vouchers attesting their quality such as
quality assurance certificate etc.
3
.
The specifications, quantities, route directions and laying position of the cables to be laid
should meet the design requirements of construction drawings. The laying length of each cable
should be determined according to its actual position.
4
.
No intermediate break or joint is allowed for the cables to be laid.