SICOM6000 User’s Manual
-20-
Figure 3‐13: 5.08mm‐spacing terminal block
2.
RS232 CONSOLE interface
The CONSOLE interface of SICOM6000 is a shielded RJ45 connector and its interface
communication standard is 3‐wire RS232. Users can use a network management cable with one
end bearing RJ45 plug and the other end DB9F plug to connect CONSOLE interface with the 9‐pin
serial port in the control computer. Operate the hyper terminal in the control computer to
configure SICOM6000 by CLI command. The cable wiring sequence is shown in the following
Figure:
Setting parameters for hyper terminal port: Baud rate: 9600; Data bit: 8; Parity check: None; Stop
bit: 1; Data flow control: None.
Figure 3‐14 CONSOLE wiring sequence
3.
Terminal block for relay alarm output
For the device with single power input, it offers power loss alarm; for the device with dual
redundant power inputs, it provides single power input alarm and power loss alarm. And single
power input alarm can be set by network management software.
For power loss alarm, when the power is supplied smoothly, the normally open contact of the
alarm relay is on and the normally closed contact is off; when the power supply is cut off, the