Chapter 6 - TV Measuring Range
43
10713 Vxx.11
To show the impulse response on the TFT of the measuring instrument, select the menu item
IMPULSERES
. A menu for additional settings will then appear.
Figure 6-14 DVB-T Impulse response menu options
You can “freeze” the picture using
FREEZE
. You can expand the impulse response in the
horizontal direction using
ZOOM
. You can then see more details near the primary impulse. You
can define the unit of the x-axis with
µs
or
km
. Time and length are related via the speed of light,
c: =3•10
8
m/s. You can end the display of the impulse response via the menu item
BACK
.
Figure 6-15 DVB-T Impulse response
Figure 6-15 shows an impulse response with a primary impulse (left picture edge) and several
secondary impulses at a distance of approximately 23 km from the primary impulse.
You can move the cursor (small triangle) left and right using the
←/→
keys. At the top area of the
screen, the distance of the secondary impulses and their attenuation (-21 dB) in relation to the
primary impulse is displayed.