Chapter 7 - FM (VHF) Measuring Range
61
10713 Vxx.11
7.6
Level measurement
As soon as the instrument is tuned to a frequency, it begins to measure the level and displays the
measured value in dBµV. The measuring range is from 25 to 110 dBµV with a resolution of 0.1 dB.
The measuring rate for the numerical level value is approx. 3 Hz.
7.6.1
Acoustic level trend
When no line of sight to the measuring instrument exists while lining up an antenna, an acoustic
level trend signal can be switched on. A sound signal is emitted from the loudspeaker. Its frequency
changes in proportion to the measured level. When the level increases, the frequency goes up and
vice versa. The sound signal can be switched on and off via the menu item
ACOU. LEVEL
.
When the sound signal is switched on, the menu item is displayed inverted.