SECTION 4A
Electrical Functions and Precautions
(STRAIGHT BLADE SHEAR)
Forward and Reverse are controlled by a drum switch at the exit end right side of
machine. The drum switch is used to run the gutter forward, reverse and jog to length.
Entrance emergency switch, located at entrance end right side, is here for your
safety while feeding a new coil.
Duplex outlets are provided at the exit end below the drum switch for your
convenience.
When operating your new PANTHER, you will need to use an extension cord. The
table below gives the minimum extension cord wire gauge recommended by the motor
manufacturer. The cord size needs to be adhered to in order to MAINTAIN WARRANTY
ON MOTOR.
A minimum 4500 watt generator should be used with your machine.
EXTENSION CORD TABLE
LENGTH OF CORD WIRE GAUGE (COPPER WIRE)
UP TO 25'
12 GA.
25 TO 50'
10 GA.
50 TO 100'
7 GA.