© 2016 Spectrum Brands, Inc. 

3.  Inclusion Procedures 

1.

 

Power the lock by placing the battery pack into the lock 

2.

 

On the controller, select the option to add a device. 

3.

 

On the lock, press button ‘A’.  The red LED will illuminate until the add request has been processed. 

 

4.  Exclusion Procedures 

1.

 

Power the lock by placing the battery pack into the lock 

2.

 

On the controller, select the option to remove a device 

3.

 

On the lock, press button ‘A’.  The red LED will illuminate until the removal request has been 
processed. 

 

5.  Reset Procedures 

A factory reset will delete all codes associated with the lock and will remove it from your smart home 
system.  It will not remove any anti-theft settings. 

Please use the local reset procedure only when the primary controller is missing or inoperable. 

5.1  Local 

1.

 

Remove battery pack and press the program button a few times to discharge. 

2.

 

Press and hold the program button. 

3.

 

Replace the battery pack. 

4.

 

Continue holding the program button for 30 seconds until the lock beeps and the state LED flashes red. 

5.

 

Press the program button again.  The status LED will flash green. 

6.

 

When the cycle of red and green flashes ends, the reset has completed. 

7.

 

Wait for the lock to reboot. 

5.2  Remotely 

1.

 

From a controller, write a 0x01 to configuration parameter 40. 

2.

 

When the cycle of red and green flashes ends, the reset has completed. 

3.

 

Wait for the lock to reboot. 

Содержание Smartcode 888

Страница 1: ... D Is the door edge chiseled Which latch are you installing YES NO Use latch A If the latch bolt is not already extended extend the latch bolt as shown wood block actual size Use latch B not included If the latch bolt is not already extended extend the latch bolt as shown Latch A Latch B S 2x C Q 2x Longer screws install closest to the door jamb door frame E Install strike on the door frame Make s...

Страница 2: ...ng plate A A A B B C D B C Diameter is 2 1 8 54 mm Diameter is 1 1 2 38 mm or D is required for installation Install D on F D is not needed for installation Discard D Cable goes underneath latch Support exterior assembly during mounting plate installation Route cable through center hole then push cable into bottom hole Insert key and test latch If latch does not extend or retract smoothly adjust s...

Страница 3: ...attery pack or back panel slide up the window on the interior cover Locking the Door Unlocking the Door Re Key with SmartKey Enter user code A total of 30 user codes may be programmed Press Lock button once A A B B C What lights and sounds does the lock produce D Each user code must be a unique code between 4 and 8 digits depending on your smart home system Programming was successful Programming w...

Страница 4: ...ssure interoperability each Z Wave product must pass a stringent conformance test to assure that it meets the Z Wave standard for complete compliance with all other devices and controls The Z Wave identity mark assures consumers integrators dealers and manufacturers that their products will reliably perform with any other Z Wave device And regardless of the vendor always powered nodes may act as a...

Страница 5: ...tion Parameters The Z Wave door lock module supports the use of the configuration command class to provide advanced configuration of the door lock over the Z Wave network This section describes the configuration parameters supported by the door lock 2 1 Configuration Parameters 33 and 34 Parameter Name SKU length 8 bytes Data Length 4 bytes each parameter Default Values for 33 and 34 0x20 0x20 0x2...

Страница 6: ...ng a set command with the default field set to 1 will cause the control to revert back to its factory default setting 2 3 Configuration Parameter 36 Parameter Name Auto lock Feature Control Data Length 2 bytes Default Values Byte 1 0 disabled Byte 2 0x1E HEX 30 seconds Possible Values Byte 1 1 enabled 0 disabled Byte 2 30 60 90 120 180 all in seconds Description The configuration parameter 36 uses...

Страница 7: ...40 is a one byte field used to set the lock to its default setting known as a factory reset command Reading this parameter will always return a value of 0 Writing a value of 1 to this parameter will cause both the lock and Z Wave card to reset back to their default settings and will remove itself from the network All network information including associations will be cleared 2 6 Configuration Para...

Страница 8: ...k and will remove it from your smart home system It will not remove any anti theft settings Please use the local reset procedure only when the primary controller is missing or inoperable 5 1 Local 1 Remove battery pack and press the program button a few times to discharge 2 Press and hold the program button 3 Replace the battery pack 4 Continue holding the program button for 30 seconds until the l...

Отзывы: