background image

 

© 2016 Spectrum Brands, Inc. 

 

1.  Association Groups 

The lock supports 2 association groups.  Per Z-Wave Plus requirements, group 1 is 
assigned to the Lifeline group and can only support 1 node. 

The Lifeline group supports the following unsolicited messages: 

 

Command Class 

Command 

Command Class Battery 

Battery Report 

Command Class Door Lock 

Door Lock Operation Report 

Command Class Notification 

Notification Report 

Command Class Device Reset Locally 

Device Reset Locally Notification 

 

Association group 2 is identified as the “Doorlock notify report” group.  It allows at 
most 5 other nodes to be associated with the lock and will provide all Notification 
Reports, via the Command Class Notification, generated by the lock. 

2.  Configuration Parameters 

The Z-Wave door lock module supports the use of the configuration command class to 
provide advanced configuration of the door lock over the Z-Wave network.  This section 
describes the configuration parameters supported by the door lock. 

2.1  Configuration Parameters 33 and 34 

Parameter Name:  SKU (length = 8 bytes) 

Data Length:  4 bytes (each parameter) 

Default Values for 33 and 34:  0x20, 0x20, 0x20, 0x20 (all spaces) 

Possible Values:  All printable characters will be accepted 

Description: 

The configuration parameters 33 and 34 are used to set and get the SKU part numbers.  
The SKU is made up of 8 bytes.  Each parameter consists of four bytes of data.  
Parameter 33 contains the first four most significant bytes of the SKU, while parameter 
34 contains the four least significant bytes of the SKU. 

When setting the SKU, it must be done in two set commands, one for each parameter.  
The order of programming the SKU does not matter. 

Содержание Smartcode 888

Страница 1: ... D Is the door edge chiseled Which latch are you installing YES NO Use latch A If the latch bolt is not already extended extend the latch bolt as shown wood block actual size Use latch B not included If the latch bolt is not already extended extend the latch bolt as shown Latch A Latch B S 2x C Q 2x Longer screws install closest to the door jamb door frame E Install strike on the door frame Make s...

Страница 2: ...ng plate A A A B B C D B C Diameter is 2 1 8 54 mm Diameter is 1 1 2 38 mm or D is required for installation Install D on F D is not needed for installation Discard D Cable goes underneath latch Support exterior assembly during mounting plate installation Route cable through center hole then push cable into bottom hole Insert key and test latch If latch does not extend or retract smoothly adjust s...

Страница 3: ...attery pack or back panel slide up the window on the interior cover Locking the Door Unlocking the Door Re Key with SmartKey Enter user code A total of 30 user codes may be programmed Press Lock button once A A B B C What lights and sounds does the lock produce D Each user code must be a unique code between 4 and 8 digits depending on your smart home system Programming was successful Programming w...

Страница 4: ...ssure interoperability each Z Wave product must pass a stringent conformance test to assure that it meets the Z Wave standard for complete compliance with all other devices and controls The Z Wave identity mark assures consumers integrators dealers and manufacturers that their products will reliably perform with any other Z Wave device And regardless of the vendor always powered nodes may act as a...

Страница 5: ...tion Parameters The Z Wave door lock module supports the use of the configuration command class to provide advanced configuration of the door lock over the Z Wave network This section describes the configuration parameters supported by the door lock 2 1 Configuration Parameters 33 and 34 Parameter Name SKU length 8 bytes Data Length 4 bytes each parameter Default Values for 33 and 34 0x20 0x20 0x2...

Страница 6: ...ng a set command with the default field set to 1 will cause the control to revert back to its factory default setting 2 3 Configuration Parameter 36 Parameter Name Auto lock Feature Control Data Length 2 bytes Default Values Byte 1 0 disabled Byte 2 0x1E HEX 30 seconds Possible Values Byte 1 1 enabled 0 disabled Byte 2 30 60 90 120 180 all in seconds Description The configuration parameter 36 uses...

Страница 7: ...40 is a one byte field used to set the lock to its default setting known as a factory reset command Reading this parameter will always return a value of 0 Writing a value of 1 to this parameter will cause both the lock and Z Wave card to reset back to their default settings and will remove itself from the network All network information including associations will be cleared 2 6 Configuration Para...

Страница 8: ...k and will remove it from your smart home system It will not remove any anti theft settings Please use the local reset procedure only when the primary controller is missing or inoperable 5 1 Local 1 Remove battery pack and press the program button a few times to discharge 2 Press and hold the program button 3 Replace the battery pack 4 Continue holding the program button for 30 seconds until the l...

Отзывы: