www.kvarta.net
5
/
32
5
DVB Monitor M1 User Manual 2.21
2.2.
GENERAL SPECIFICATIONS OF THE DVB MONITOR
Communication ports
Ethernet
100baseT – Web Server and UDP/TCP (SNMP/ASCII)
Frequency range and Modulation
Frequency Range
46 MHz - 1004 MHz
Analog TV
NTSC , PAL/SECAM
Digital TV
DVB-T/T2,
DVB-H,
DVB-C, DVB-S/S2
Demodulator
DVB-T
ETSI EN 300 744
DVB-H
ETSI EN 300 744 Annex F
DVB-C
ETSI EN 300 429 and ITU J.83 Annex A/C
Supports
QPSK/16/32/64/128/256QAM
Bandwidth
6MHz/7MHz/8MHz
Symbols rate
1MS/S-7MS/S
COFDM
2k,4k,8k
Measurements
Standard
ETSI TR 101 290 V1.2.1
Level
30dBuV - 100dBuV (±2dBuV)
MER
19dB - 45dB (±2dB)
C/N
19dB - 45dB (±2dB)
SNR
19dB - 55dB (±2dB)
BER (DVB-C)
1E-1~ 1E-7
CBER,VBER (DVB-T)
1E-1~ 1E-7
LBER (DVB-T2)
1E-1~ 1E-7
MER,BER (DVB-S)
1E-1~ 1E-7
MER,BER (DVB-S2)
1E-1~ 1E-7
MPEG Decoding
Tables
PAT,PMT,SDT,TDT,TOT
Alarms
Service Audio/Video alarms with e-mail notifications and SNMP traps
Monitoring
Alarms
Carrier count, Level(low, high), SNR(low), C/N(low), MER(low),
BER(high), CBER(high), VBER(high), PAT/PMT/Audio/Video missing alarm
Log, E-mail, SNMP traps
Available
Power Supply
Supply voltage
230V/115V
Voltage tolerance
+/- 10%
Main AC frequency
45-65 Hz
Fuse
0.8A
Consumption
10 VA
Mechanical aspects
Height
1U (44,5 mm)
Width
483 mm
Depth
220 mm
Net weight
2,5 kg
Info
Updates
Available
Front panel LEDs
Power supply, LAN, Alarm