www.kvarta.net
30
/
32
30
DVB Monitor M1 User Manual 2.21
DVBC_SYMBOLS read-write Default symbol rate 1000 -
7000
DVBC_SPECTRUM read-write 0-Normal, 1-Inverted
TUNE_SAVE COMMAND Save tuner configuration
TUNE_NEXT COMMAND Go to next carrier
TUNE_PREV COMMAND Go to previous carrier
ALARM_CHECK read-write Alarm checks before sending e-
mail or snmp trap.
--
-- The 'FREQUENCY_FILE' group;
--
FREQUENCY_FILE.FILENAME read-write Filename of the frequency file
FREQUENCY_FILE.SAVE COMMAND Saves all monitoring
frequencies.
FREQUENCY_FILE.LOAD COMMAND Loads all monitoring
frequencies from file.
--
-- The 'F' table;
--
F(???).ATV read-write Set frequency or scan range
F(???).DVBC read-write Set frequency or scan range
F(???).DVBT read-write Set frequency or scan range
--
-- The 'ATV' group;
--
ATV.EXPECTED read-write Expected carriers during
monitoring
ATV.EXPECTED_ON read-write Carrier count alarm On/Off
ATV.TIMEOUT read-write Scan timeout in seconds
ATV.TIMEOUT_ON read-write Scan timeout alarm On/Off
ATV.LEVEL_LOW read-write Low level threshold in dBuV
ATV.LEVEL_LOW_ON read-write Low level alarm On/Off
ATV.LEVEL_HIGH read-write High level threshold in dBuV
ATV.LEVEL_HIGH_ON read-write High level alarm On/Off
ATV.SNR_LOW read-write SNR low level threshold in dB
ATV.SNR_LOW_ON read-write SNR low level alarm On/Off
ATV.LOST_ON read-write Carrier lost alarm On/Off
--
-- The 'DVBC' group;
--
DVBC.EXPECTED read-write Expected carriers during
monitoring
DVBC.EXPECTED_ON read-write Carrier count alarm On/Off
DVBC.TIMEOUT read-write Scan timeout in seconds
DVBC.TIMEOUT_ON read-write Scan timeout alarm On/Off
DVBC.LEVEL_LOW read-write Low level threshold in dBuV
DVBC.LEVEL_LOW_ON read-write Low level alarm On/Off
DVBC.LEVEL_HIGH read-write High level threshold in dBuV
DVBC.LEVEL_HIGH_ON read-write High level alarm On/Off
DVBC.CNR_LOW read-write SNR low level threshold in dB
DVBC.CNR_LOW_ON read-write SNR low level alarm On/Off
DVBC.MER_LOW read-write MER low threshold in dB
DVBC.MER_LOW_ON read-write MER low alarm On/Off
DVBC.BER_HIGH read-write BER high threshold 0=1e-
7,1=1e-6 ...max 7