Step 1: Calibrate the Carriage Stop
KVAL Operation Manual
3-11
Step 1: Calibrate the Carriage Stop
For this calibration, make sure the distance from the cutting space to the first carriage stop is at 20
inches.
Important:
The
Carriage Stop
is the starting reference for the calibrations on the
machine. Always verify the carriage stop setting before continuing to cal
-
ibrate.
Movable Stop
Fixed Stop