VHD5100 · Getting started
Rack Mounting
VHD5100 will mount in standard 19" rack systems. Integral rear mounting rack ears are also provided for additional support,
do not rely on fixing and mounting the amplifiers using just the front panel as support. Use eight screws and washers to mount
the amplifier to the equipment rack rails (four for the front and four for the rear).
We recommend using a shock mounted rack for touring use to prolong the life of your VHD5100 amplifiers.
Cooling
The VHD5100 amplifier is cooled with two shock mounted fans, that moves air from front panel through dust filters across
the heatsinks and exhausts through the rear.
Although this unit is simple to operate, improper use can be dangerous. This is a very high-powered device that can put out
high voltages and sizeable currents.
It is important to have an adequate air supply at the front of the amplifier, and enough space around the rear of the amplifier
to allow the cooling air to escape. If the unit is rack mounted, do not use doors or covers on the rear of the rack; the exhaust
air must flow without restriction. If you are using racks with closed backs, use fans on the rear rack panel to ensure an ample
air supply.
AC Requirements
Two PowerCon cables are provided to connect theVHD5100 Amplifier to a suitable AC power supplies. Each cable powers
each separate amplifier channel for sufficient current delivery.
THE VHD5100 REQUIRES A GROUND CONNECTION. ALWAYS USE A GROUNDED OUTLET AND PLUG.
The PowerCon is a connector without breaking capacity, i.e. the PowerCon should not be connected or disconnected under
load or while it is live. Always isolate your AC supply before disconnecting the PowerCon connector.
The VHD5100 amplifier operates in either 115V, 230V or 250V modes. Although pre-confiured at the factory, the unit's
operating voltage mode can be changed in the fild. Amplifier power plug must remain readily operable.
Your amplifier will be supplied preset to the voltage used in your area. The table below provides typical current draw fiures
for the VHD5100 Amplifier.
Remember that if you are connecting both AC cables for the VHD5100 to the same AC power source then you will need to
have double the per channel current available.
AC Input
Current draw with amplifier running
at Average Power (Each Channel)
Current draw with amplifier running
at Peak Power (Each Channel)
250V
3.2A
5A
230V
3.5A
5.4A
115V
7A
11A
To indicate that caution is necessary when operating the device or control close to where the symbol
is placed, or to indicate that the current situation needs operator awareness or operator action in order
to avoid undesirable consequences.
This device is not suitable for use in places
where children may be present.
20
VHD5100 · G
etting star
ted
Содержание KVV 987 334
Страница 10: ...VHD5000 Drawing Drawing 9 VHD5000 Drawing 481 4 484 9 431 6 101 7 463 8 177 8 95 451 9 7 10 3 A 1 1 A ...
Страница 12: ...VHD5000 Block Diagram Block Diagram 11 VHD5000 Block Diagram ...
Страница 17: ...VHD5000S Drawing Drawing 7 10 3 8 95 451 9 484 9 481 4 431 6 177 463 8 101 7 A 1 1 A 16 VHD5000S Drawing ...
Страница 19: ...18 VHD5000S Block Diagram VHD5000 S Block Diagram Block Diagram ...
Страница 24: ...VHD5100 Drawing Drawing 463 8 101 7 108 7 8 95 445 95 481 4 177 7 10 3 484 9 A A 1 1 23 VHD5100 Drawing ...
Страница 28: ...VHD5100 Block Diagram DOWNFILL 27 VHD5100 Block Diagram VHD5100 Block Diagram Channel DOWNFILL ...
Страница 29: ...VHD5100 Block Diagram VHD5100 Block Diagram Channel FILL 28 VHD5100 Block Diagram ...
Страница 35: ...VHD5 0 Amplifiers Notes 34 VHD5 0 Amplifiers Notes ...
Страница 36: ...VHD5 0 Amplifiers Notes 35 VHD5 0 Amplifiers Notes ...
Страница 37: ...VHD5 0 Amplifiers Notes 36 VHD5 0 Amplifiers Notes ...