background image

VHD5.0 A

mplifiers  ·  I

mp

or

tan

t S

af

et

y I

nstr

uc

tions

VHD5.0 Amplifiers

 · 

Important Safety Instructions

 

Important Safety Instructions

Before using your VHD5.0 Amplifiers, be sure to carefully read the applicable items of these operating instructions  

and the safety suggestions. 

  1.  Read all product instructions.
  2.  Keep printed instructions, do not throw away.
  3.  Respect and rewiew all warnings.
  4.  Follow all instructions.
  5.  Do not use this unit near water, in unprotected out door areas or in rain or wet conditions.
  6.  Clean only with dry cloth.
  7.  Do not block any ventilation openings.
  8.  Install in accordance with KV2 Audio's recommended installation instructions.
  9.  Do not install near any heat sources such as heat radiators, heat registers, stoves or other apparatus
 

  that produce heat.

 10.  Do not defeat the safety purpose of the grounding type plug. A grounding type plug has two blades
 

  and a third grounding connector. The third connector is provided for your safety. If the provided plug  

 

  does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

 11.  Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles.
 

  The AC mains plug or appliance coupler shall remain readily accessible for operation.

 12.  Only use accessories specified by KV2 Audio.
 13.  Install the product only with rigging specified by KV2 Audio, or sold with the loudspeaker.
 14.  Unplug this loudspeaker during lightning storms or when unused for long periods of time.
 15.  Refer all servicing to qualified service personnel. Servicing is required when the loudspeaker has been
 

  damaged in any way, such as when the power-supply cord or plug has been damaged; liquid has been  

 

 

  spilled or objects have fallen into the loudspeaker; rain or moisture has entered the loudspeaker;  

 

  the loudspeaker has been dropped; or when for undetermined reasons the loudspeaker does not operate    

   normally.
 16.  Do not remove front or back panels. Removal of the panel will expose hazardous voltages.
 

  There are no user serviceable parts inside and removable may void the warranty.

 17.  An experienced user shall always supervise this professional audio equipment.  

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE THE PANELS.
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL. 

WARNING: 

To prevent fire or electric shock, do not expose this equipment to rain or moisture. 

SAFETY SUMMARY
To reduce the risk of electric shock, disconnect the loudspeaker from the AC mains before installing audio cable.
Reconnect the power cord only after making all signal connections. Connect the loudspeaker to a twopole, three- wire
grounding mains receptacle. The receptacle must be connected to a fuse or circuit breaker. Connection to any other
type of receptacle poses a shock hazard and may violate local electrical codes. Do not allow water or any foreign object
to get inside the loudspeaker. Do not put objects containing liquid on or near the unit. To reduce the risk of overheating the 
loudspeaker, avoid exposing it to direct sunlight. Do not install the unit near heat-emitting appliances, such as a room heater 
or stove. This loudspeaker contains potentially hazardous voltages. Do not attempt to disassemble the unit. The unit contains 
no user serviceable parts, repairs should be performed only by factory trained service personnel.

To indicate that caution is necessary when operating the device or control close to where the symbol  

is placed, or to indicate that the current situation needs operator awareness or operator action in order 

to avoid undesirable consequences. 

This device is not suitable for use in places  

where children may be present.

Содержание KVV 987 334

Страница 1: ...constantly develop technologies that eliminate distortion and loss of information providing a true dynamic representation of the source Our aim is to create audio products that absorb you place you within the performance and deliver a listening experience beyond expectations VHD5000 VHD5000S VHD5100 ...

Страница 2: ...into the loudspeaker rain or moisture has entered the loudspeaker the loudspeaker has been dropped or when for undetermined reasons the loudspeaker does not operate normally 16 Do not remove front or back panels Removal of the panel will expose hazardous voltages There are no user serviceable parts inside and removable may void the warranty 17 An experienced user shall always supervise this profes...

Страница 3: ...ram 11 VHD5000S 12 Introduction 12 Getting started 13 Features Front panel 14 Features Rear panel 15 Drawing 16 Specifications 17 Block Diagram 18 VHD5100 19 Introduction 19 Getting started 20 Features Front panel 21 Features Rear panel 22 Drawing 23 Using the System 24 25 Specifications 26 Block Diagram 27 28 VHD5 0 Power Unit 29 Front Panel 29 Rear Panel 30 Wiring Scheme 31 Basic configuration 3...

Страница 4: ... maximum current for the amplifiers The VHD5 amplifier unit provides complete audio system control including equalisation overdrive protection thermal protection and user adjustable set up parameters The Amplifier incorporates a graphic 5 7 sunlight readable touch control panel for easy setup and synoptic overview over all systems with Ethernet remote control possibility The VHD5000 amplifier can ...

Страница 5: ...e to use a VHD LD4 Line Driver in addition at the mixer outputs to ensure that the line to the amplifier is driven correctly and the signal integrity maintained The VHD5000 also features long distance eq high frequency recovery and a signal generator The amplifier is equipped with multiple network possibilities for easy remote control operation from networked amplifiers or website applications The...

Страница 6: ... If you are using racks with closed backs use fans on the rear rack panel to ensure an ample air supply AC Requirements Two PowerCon 32A cables are provided to connect the VHD5000 to a suitable AC power supply The PowerCon 32A is a connector without breaking capacity i e the PowerCon should not be connected or disconnected under load or while it is live Always isolate your AC supply before disconn...

Страница 7: ...User Guide for more information 2 Lock Standby This illuminated pushbutton serves for setup lock or for standby mode when long pressed This pushbutton is green in normal power on state and illuminates red when standby mode is activated 3 Enter The Rotation encoder with Enter push button The encoder serves as the main way for increasing clockwise or decreasing counterclockwise values and menu posit...

Страница 8: ...ock diagram for more information 4 Low Out Serves as a low mid signal output for the adjacent VHD5000S amplifier 5 Fill Out This serves as a fill signal output with the possibility of tunable HPF and delay 6 Sub A Front Out Subwoofer A signal output provides processed outputs for feeding various subwoofers When the cardioid mode is set it then serves as an output for the front subwoofer 7 Sub B Re...

Страница 9: ...ans during high temperature conditions Air enters through the front panel dust filters and exits through the rear Be sure to allow adequate air flow to the front of the rack in which the VHD5000 is mounted COMMUNICATION 11 Internal Out Serves as a internal communication signal output for the adjacent VHD5000S amplifier and Power rack unit Serves for remote control of adjacent devices 12 Ethernet S...

Страница 10: ...VHD5000 Drawing Drawing 9 VHD5000 Drawing 481 4 484 9 431 6 101 7 463 8 177 8 95 451 9 7 10 3 A 1 1 A ...

Страница 11: ...2kHz Signal Input Input Channels XLR Input Sensitivity 1 5V RMS Input Impedance 10kΩ to 120Ω Line driver ready Signal Output Output channels Through Low Sub A B Fill Insert Speaker Output Speaker Output AP6 Features Level Control 32 6dB Hi Level Control 3 3dB Mid Bass Level Control 6 6dB Subwoofer Level Control 6 10dB System setup 3x Indicators 5 7 sunlight readable color display Remote control K ...

Страница 12: ...VHD5000 Block Diagram Block Diagram 11 VHD5000 Block Diagram ...

Страница 13: ...assis The unit acts as a slave for the VHD5000 which provides audio and control signal VHD5000S part number KVV 987 356 230V Application Specifically designed as the amplification and control unit for powering the 1xLow Mid VHD5 0 part and 3xVHD8 10 loudspeakers in a rack mount module Large scale Portable PA Fixed installations Large clubs 177 481 4 177 431 6 177 451 9 Rear Panel Front Panel Side ...

Страница 14: ...w without restriction If you are using racks with closed backs use fans on the rear rack panel to ensure an ample air supply AC Requirements Two PowerCon 32A cables are provided to connect the VHD5000S to a suitable AC power supply The PowerCon 32A is a connector without breaking capacity i e the PowerCon should not be connected or disconnected under load or while it is live Always isolate your AC...

Страница 15: ... unit will Auto Reset after it cools down to a safe operating temperature 4 System error These red LED s indicate when the amplifier detects any trouble More information can be found using display or remote control software 5 Communication The green LED indicates successful communication with the adjacent VHD5000 amplifier 6 Standby The yellow LED indicates when the amplifier is switched into stan...

Страница 16: ...rs through the front panel dust filters and exits through the rear Be sure to allow adequate air flow to the front of the rack in which the VHD5000S is mounted COMMUNICATION 5 Internal Out Serves as a internal communication signal output for the adjacent VHD5000S amplifier and Power rack unit Serves for remote control of adjacent devices 15 VHD5000S Features Rear panel AC IN B WWW KV2AUDIO COM DES...

Страница 17: ...VHD5000S Drawing Drawing 7 10 3 8 95 451 9 484 9 481 4 431 6 177 463 8 101 7 A 1 1 A 16 VHD5000S Drawing ...

Страница 18: ...utput Output channels Through Out Speaker Output Speaker Output 2x AP4 Features Indicators 2x Power ON Thermal Signal Limiter Communication Remote control Internal RS485 Power Power Connector 2x Neutrik PowerCon 32A Operating Voltage 230V Operating Voltage Range 205 to 250V 50 60Hz Recommended Amperage 2x20A 205V 2x16A 230V Soft Start YES Protection Thermal breaker Cooling Front to back active Phy...

Страница 19: ...18 VHD5000S Block Diagram VHD5000 S Block Diagram Block Diagram ...

Страница 20: ...lation amplifier for high frequencies 200 watt Class AB push pull low intermodulation design for mids and a 1000 watt high efficiency current enhancing switch mode technology amplifiers for bass VHD5100 part number KVV 987 438 230V Application Specifially designed as the amplifiation and control unit for powering the 1x VHD5 1 Downfill and 1x ESR215MkII as a general use Fill module Large scale Por...

Страница 21: ...plifier to a suitable AC power supplies Each cable powers each separate amplifier channel for sufficient current delivery THE VHD5100 REQUIRES A GROUND CONNECTION ALWAYS USE A GROUNDED OUTLET AND PLUG The PowerCon is a connector without breaking capacity i e the PowerCon should not be connected or disconnected under load or while it is live Always isolate your AC supply before disconnecting the Po...

Страница 22: ...service personnel to have it serviced 2 Speaker Protection Yellow LED indicates that the audio limiter has been activated This RMS limiter protects speakers against overload 3 Signal Present Green LED indicates when audio signal is present at the amplifier input 4 Power On Thermal Auto reset Green LED indicates that the AC power is on When red it indicates that the thermal limit of the VHD5100 Amp...

Страница 23: ...ment circuitry ON position which boosts frequencies around 60Hz to enhance the lowest frequency band 7 Powercon Power Connectors The VHD5100 Amplifier uses two connectors per two channel Each connector supplies one channel They accept standard PowerCon terminated AC Mains cables 8 Fans The cooling fans operate continuously while the amplifier is on An internal temperature sensor increases the spee...

Страница 24: ...VHD5100 Drawing Drawing 463 8 101 7 108 7 8 95 445 95 481 4 177 7 10 3 484 9 A A 1 1 23 VHD5100 Drawing ...

Страница 25: ...24 VHD5100 Using the System VHD5100 Using the System Full range setup FILL ESR215MkII DOWNFILL VHD5 1 Downfill FILL DOWNFILL FILL IN DOWNFILL IN ...

Страница 26: ...SR215MkII DOWNFILL VHD5 1 Downfill FILL IN DOWNFILL IN Set VHD5100 Amplifier to FULL RANGE OFF mode Signal is crossed over at Hi Mid for ESR215MkII cabinets and SUB for external subwoofer Crossover frequency is app 70Hz SUB SET UP LEVEL setting depends on subwoofer type and music style ...

Страница 27: ...w Frequency Amplifier Specification Type High efficiency Current enhancing switch mode Rated Continuous Power 1000W Distortion 0 02 Operating Bandwidth 10Hz to 400Hz Signal Input Input Sensitivity Fill 1 0V RMS Input Impedance 20kΩ balanced Input Sensitive DownFill 0 5V RMS Speaker Output Speaker Output 2x AP6 female Power Power Connector 2x Neutrik PowerCon Operating Voltage 115V 230V 250V Operat...

Страница 28: ...VHD5100 Block Diagram DOWNFILL 27 VHD5100 Block Diagram VHD5100 Block Diagram Channel DOWNFILL ...

Страница 29: ...VHD5100 Block Diagram VHD5100 Block Diagram Channel FILL 28 VHD5100 Block Diagram ...

Страница 30: ... motor movement is indicated using the red tilt light When the motor reaches its limit position the motor automatically stops and the red light goes off When the tilt light flashes the motor output is overloaded and a reversable fuse is activated or during startup 5 Ethernet and signal XLR inputs and outputs interconnections The VHD5 Power Unit serves as a interconnection of signal power and data ...

Страница 31: ...irs mains power input Each output is marked with phase marking 6 230 VAC 8 A L1 and L2 power sockets Is a 230V mains power output for powering adjacent devices such as VHD5100 or processors Maximum power output is 8A RMS 7 L1 2 3 Fuses Mains fuses for power outputs Neutrik PowerCon Rack Mounting VHD5000 will mount in standard 19 rack systems Integral rear mounting rack ears are also provided for a...

Страница 32: ...al XLR internal comunication XLR KV2 NET comunication between VHD5 systems XLR Ethernet CATS Amphenol 6P LK Link 8P Mid Hi speaker output Amphenol 4P LK Link 9P Mid Low speaker output Powercon Amphenol 6P Downfill speaker output signal FILL IN mixing console 31 VHD5 0 Power Unit Wiring Scheme ...

Страница 33: ...AME COLOUR AS THIS PANEL REFER TO OWNER S MANUAL TO ENSURE PROPER CONNECTION WARNING SERIAL NUMBER WWW KV2AUDIO COM B A S S M O D U L E 8 10 VHD5000 DESIGNED BY KV2 AUDIO MANUFACTURED IN THE EUROPEAN UNION CONNECT TO CONNECT VHD5000 USE THE CONNECTOR OF THE SAME COLOUR AS THIS PANEL REFER TO OWNER S MANUAL TO ENSURE PROPER CONNECTION WARNING SERIAL NUMBER WWW KV2AUDIO COM B A S S M O D U L E 8 10 ...

Страница 34: ...ed distributor service centre or shipped directly to the KV2 Audio factory Because of the complexity of the design and the risk of electrical shock all repairs must be attempted only by qualified technical personnel If the unit needs to be shipped back to the factory it must be sent in its original carton If improperly packed the unit may be damaged To obtain service contact your nearest KV2 Audio...

Страница 35: ...VHD5 0 Amplifiers Notes 34 VHD5 0 Amplifiers Notes ...

Страница 36: ...VHD5 0 Amplifiers Notes 35 VHD5 0 Amplifiers Notes ...

Страница 37: ...VHD5 0 Amplifiers Notes 36 VHD5 0 Amplifiers Notes ...

Страница 38: ...KVV120124 00 04 0 KV2 Audio International Nádražní 936 399 01 Milevsko Czech Republic Tel 420 383 809 320 Email info kv2audio com www kv2audio com The Future of Sound Made Perfectly Clear ...

Отзывы: