System Exclusive Control of KDFX Parameters
Appendix C-2
40
Mix send for Aux bus
41
Final Mix
42
Effect preset for Aux bus
43-46
Effect preset for FXBusses 1-4
Parameters
Here are the valid parameters for each Device (numbers are decimal):
Device Parameter
Description
0-15
0
Level
0-15
1
Pan or Balance
0-15
2
Width (only for stereo inputs)
16-31
0
Gain (or frequency if hipass or lopass)
16-31
1
Frequency
32-41
0
Level
32-41
1
Balance
42-46
0
Wet/Dry (or In/Out)
42-46
1-43
Depends on the Effect
The following example sets the wet/dry mix for the Aux bus effect to 50%:
F0 07 00 78 1B
(standard header)
2A
(Device 42 decimal)
00
(Parameter = Wet/Dry)
00
(MSB = there isnÕt any)
32
(LSB = 50 decimal)
F7
(End of Exclusive)
The same example in decimal reads:
240, 7, 0, 120, 27, 42, 0, 0, 50, 247
Under Sysex control, KDFX parameter values are not mapped through display tables, but
instead are handled as ÒrawÓ numbers. So while on the K2500Õs LCD you might set
ÒRoomTypeÓ to ÒHall2Ó, under Sysex control you have to determine the number of the
parameter and the number corresponding to the value you want: in this case, you would set
parameter 8 to a value of 7.
Signed and Unsigned values
Parameters are either signed or unsigned. Unsigned parameters can range from 0 to 255, signed
parameters can range from -128 to 127. For unsigned values above 127, the MSB is 01 and the
LSB is (value - 128 decimal). For signed values below zero, the MSB is 7F (hex), and the LSB is
(value + 128 decimal). For other values, the MSB is 00.
Содержание KDFX
Страница 56: ...Inside KDFX Saving Studios and other objects 3 24...
Страница 76: ...Real time Control of KDFX KDFX in Auto Mode 4 20...
Страница 94: ...Using the Algorithms FXMod Diagnostic 5 18...
Страница 104: ...Special Topics Using the Internal Effects 6 10...
Страница 118: ...KDFX Objects KDFX Studios Appendix A 14...
Страница 154: ...KDFX Controller Assignments in Programs Setups Appendix B 36...
Страница 158: ...System Exclusive Control of KDFX Parameters Appendix C 4...
Страница 164: ...Index 6...