3BA00174 • 2014-02-06 • Rev. 5
HR 100 1 / 5
2.
Technical data
Hybrid Rework-System HR 100A, base station
Designation
Value
Unit
Mains voltage
220-240
VAC
Mains frequency
50-60
Hz
Fuse (slow blow)
2
A
Mains voltage
110-120
VAC
Mains frequency
50-60
Hz
Fuse (slow blow)
4
A
Secondary voltage
13
VAC
Maximum heating power
200
W
Safety class
I
-
Permissible ambient temperature
0-40
°C
Temperature range at outlet
30-550
°C
Air volume
With hybrid adaptor AD1
15...35
l/min
With hybrid adaptor AD2
6...11
l/min
With hybrid adaptor AD3
3...9
l/min
Miscellaneous
Function display
LED display
PC interface
Mini USB
Supply cable 2m, PVC, with appliance connector
Operation via rotary encoder with momentary contact function
Antistatic surface, suitable for use in ESD-environment, EMC-tested*.
Vacuum
-0,2...-0,4
bar
Conformity
Dimensions WxHxD
211 x 220 x 188
mm
Weight
4,5
kg