7.
Treatment of faults
7.1
General faults
If the station does not operate as expected, check the following items:
• Is main voltage present? Correctly connect the mains lead to the device and socket.
• Is the fuse defective? The fuse can be found at the rear side of the device in the mains
connecting socket.
• Note that a defective fuse may also indicate a more severe cause of fault. Simply changing
the fuse therefore generally does not suffice.
• Is the Hybrid Tool correctly connected with the base station?
7.2
Other faults
Other faults may occur, which could point to defects on the soldering tool. These are:
• The Hybrid Tool does not heat up, no effect of the Start / Stop button. The LED does not
light, the display permanently shows
. This is caused by an impermissibly high Tool
temperature. Allow the Hybrid Tool to cool down for a while. Work can be continued after
the Tool has sufficiently cooled down.
Always use the appropriate program for the corresponding Hybrid adaptor.
You thereby avoid overheating of the Hybrid Tool and poor working results. In
case of a wrong selection the system may be prematurely be switched off by
the temperature switch.