![Kurtz Ersa HR 100 A Скачать руководство пользователя страница 22](http://html.mh-extra.com/html/kurtz-ersa/hr-100-a/hr-100-a_operating-instructions-manual_2011347022.webp)
3BA00174 • 2014-02-06 • Rev. 5
HR 100 1 / 22
6.
Description of function
6.1.3.1 Heating time Hybrid Tool and heating plate
Parameter [Run time]
■
In this level you can set the maximum heating time for the Hybrid Tool. If a Rework heating
plate (option) is connected, it will also be heated over the set time. Press the rotary enco-
der to open the parameter [Run time]
:
The connected heating plate is only switched on if the energy level for the
heating plate has been set to ≥ 1. Please read paragraph [Heating Plate
Energy Level]. Moreover, the heating plate has an indicator light which lights
up during the heating process.
■
The setting range is
to
seconds. Turn the rotary encoder clockwise or anti-
clockwise, until the desired value is displayed, e.g.
. Then press the rotary encoder
to save the adjusted value and to exit the parameter [Run time]. The display shows
again.
Caution!
Do not switch off the base station during a heating phase. This
could damage the Hybrid Tool. During the cooling phase allow the Tool to cool
down for a few seconds. Then switch off the base station. In case of a power
failure or a fault during the heating phase you may hold the Hybrid Tool up,
for unobstructed heat dissipation.