3BA00174 • 2014-02-06 • Rev. 5
HR 100 1 / 35
6.
Description of function
6.3
Working with the Hybrid Tool
For lead-free processes we recommend the additional use of the optionally
available Rework heating plate IRHR100A. If the thermocouple or the IR
sensor is used for processing monitoring purposes, position the sensor in the
working range of the Hybrid Tool.
6.3.1 Soldering and desoldering
■
Choose a suitable Hybrid adaptor and mount it to the Hybrid Tool. Then choose the pro-
gram matching the adaptor.
■
Soldering:
Prepare the soldering joint on the printed circuit board with soldering flux
and/or soldering paste. Then position the component.
■
Press the Start / Stop button on the Hybrid Tool. The set time is started and the Tool
is heated up. During this process move the Tool with small circular movements over the
component, to achieve uniform heating up of the component. The display will first show
the reading
, followed by the elapsed heating time, e.g.
. During the last ten
seconds of the heating time a reminding signal will sound every second. Once the comple-
te time has elapsed, the heating time is finished and the cooling phase starts. The display
shows the reading
.
■
Once the solder has melted, press the Start / Stop button to stop the heating process and
to start the cooling phase.
Caution!
Adjacent areas will also be heated and must therefore protected
against heat.