94
H3-72-01
For internal use only
11.
Descale
11.1
EDG and EKDG
Program duration: approx. 35 minutes
The “descale” program can be selected with the OK button (menu of the OK button back – user settings
– descale).
Application
Descaling comprises the following steps:
•
The water tank, which is filled with 0.5 litres of a mixture of equal proportions of descaling agent
and water, is recognised.
•
For reasons of safety the evaporator is firstly emptied. To do so, the discharge pump is operated
for 12 seconds (software).
•
The supply pump transports the mixture into the evaporator until the level sensor recognises
water, with a certain follow-on time (slightly longer than in the standard function). The mixture is
circulated several times and is pumped in and out again.
•
After the evaporator has been filled, the mixture in the evaporator is heated up to a certain
temperature, thus speeding up the descaling process. The mixture is maintained at this
temperature for some time.
•
After which the evaporator is emptied until the level recognition is actuated, with a certain follow-on
period.
The first rinse is carried out in the following steps:
•
The water tank must be removed, emptied and filled with fresh water up to the MAX mark and then
reinstalled. On doing so, unauthorised utilisation is secured against by means of a minimum period
of 5 seconds (software) between detection, removal and installation of the water tank.
•
The rinsing liquid is transported into the evaporator up to the level recognition with a certain,
longer, follow-on time. The rinsing liquid is circulated several times.
•
Subsequent to circulation the rinsing liquid is heated up to a certain temperature [60°C]
(EEPROM) for a certain period [0 sec.] (virtually no heating up!)
•
Subsequent to heating up, the rinsing liquid is pumped off until the level recognition is actuated, in
addition to a certain follow-on time. Should the rinsing liquid exceed the permissible temperature,
the “Empty” program is started.
•
The second rinse is carried out in the following steps:
•
The water tank must be removed, emptied and filled with fresh water up to the MAX mark and then
reinstalled. On doing so, unauthorised utilisation is secured against by means of a minimum period
of 5 seconds (software) between detection, removal and installation of the water tank.
•
The rinsing liquid is transported into the evaporator up to the level recognition with a certain follow-
on time. The rinsing liquid is circulated several times.
•
Subsequent to circulation the rinsing liquid is heated up to a certain temperature [105°C] for a
certain period [120 sec.] (time-controlled heating up!).
•
After having been heated up the rinsing liquid is cooled down to a certain temperature at the same
time as emptying takes place (see EDG and EKDG auf Seite 94).
•
The cooled-down rinsing liquid is pumped out of the evaporator into the water tank until the level
recognition is actuated, in addition to a certain follow-on time.
Содержание EDG 6600.0
Страница 1: ...p l bb_a SSMMKM bad SSMMKM bhad SUMMKM bad SSMMKN bhad SUMMKN bhad SUMMKO bhad SUMMKMJTR...
Страница 29: ...H3 72 01 29 For internal use only 5 3 Water system Ignition solenoid Water tank 1 25 litres...
Страница 51: ...H3 72 01 51 For internal use only 7 1 3 Sequence diagram Steaming EEBD 6600 0...
Страница 53: ...H3 72 01 53 For internal use only Sequence diagram Regenerating EDG EKDG...
Страница 54: ...54 H3 72 01 For internal use only 7 2 2 Sequence diagram Regenerating EEBD 6600 0...
Страница 57: ...H3 72 01 57 For internal use only Sequence diagram Baking like professionals EDG EKDG...
Страница 58: ...58 H3 72 01 For internal use only 7 3 2 Sequence diagram Baking like professionals EEBD 6600 0...
Страница 97: ...H3 72 01 97 For internal use only 11 3 Flow chart Descaling programme EEBD 6600 0...