4.
Installation
4.1
Safety instructions for technicians
•
Local electricity suppliers’ statutory regulations and conditions for connection are to be fully observed.
•
The appliance must be disconnected on being connected, on carrying out repairs and when changing
a bulb. Disconnect the shock-proof plug or switch off the safety fuse.
•
Full protection against accidental contact must be guaranteed on instalment.
•
The appliance is ready to be plugged in and may only be connected to a shockproof socket which
has been installed according to specifications. Plug installation, the exchanging of terminal wires and
zero conductors or replacement of the connecting wire may only be carried out by a qualified
electrician under observance of the relevant regulations.
•
Should the plug not be accessible subsequent to installation, a universal disconnection device with a
contact clearance of at least 3 mm must be available at the installation point in order to fulfil relevant
safety regulations.
•
The built-in cupboard for the combi-steam cooker must be heat resistant up to 100 °C. This applies
in particular to veneers, overlapping edge bands, plastic surfaces, adhesives and varnishes.
Adjacent kitchen unit front panels must be heat resistant up to at least 70 °C.
•
It is essential to instal the appliance horizontally on a board which is level and stable. The board may
not bend.
•
Should the kitchen unit not be attached to the wall it must be screwed on with a standard commercial
angle.
4.2
Installation EDG / EKDG
4.2.1
in a suitable niche
Содержание EDG 6600.0
Страница 1: ...p l bb_a SSMMKM bad SSMMKM bhad SUMMKM bad SSMMKN bhad SUMMKN bhad SUMMKO bhad SUMMKMJTR...
Страница 29: ...H3 72 01 29 For internal use only 5 3 Water system Ignition solenoid Water tank 1 25 litres...
Страница 51: ...H3 72 01 51 For internal use only 7 1 3 Sequence diagram Steaming EEBD 6600 0...
Страница 53: ...H3 72 01 53 For internal use only Sequence diagram Regenerating EDG EKDG...
Страница 54: ...54 H3 72 01 For internal use only 7 2 2 Sequence diagram Regenerating EEBD 6600 0...
Страница 57: ...H3 72 01 57 For internal use only Sequence diagram Baking like professionals EDG EKDG...
Страница 58: ...58 H3 72 01 For internal use only 7 3 2 Sequence diagram Baking like professionals EEBD 6600 0...
Страница 97: ...H3 72 01 97 For internal use only 11 3 Flow chart Descaling programme EEBD 6600 0...