32
H3-72-01
For internal use only
5.5
Floor heater 140 W with protection against an excessive rise in temperature
The floor heater serves the purpose of reducing the quantity of condensate on the floor of the oven. The
quantity of water required during the cooking process can also be reduced by means of repeated
evaporation.
The floor heater is only activated in the steam cooking mode.
After completion of altitude adjustment, the floor heater is clocked at reduced power. On initial actuation
of the climatic sensor, the floor heater is switched on at full power after a certain delay.
Should the door of the oven be opened during a cooking mode, the floor heater will commence heating
at a reduced rate. The heater only works at full power again after a certain delay subsequent to initial
actuation of the climatic sensor.
The floor heater is equipped with a cutoff time lag which reacts to non-actuation of the climatic sensor
by switching off the floor heater. This occurs with some delay. The following switch-on of the evaporator
or the resulting actuation of the climatic sensor means that the floor heater is switched on again, initially
with reduced power and then, as described above, at full power.
Excessive temperature
Floor heater
Excessive temperature
Excessive temperature
Содержание EDG 6600.0
Страница 1: ...p l bb_a SSMMKM bad SSMMKM bhad SUMMKM bad SSMMKN bhad SUMMKN bhad SUMMKO bhad SUMMKMJTR...
Страница 29: ...H3 72 01 29 For internal use only 5 3 Water system Ignition solenoid Water tank 1 25 litres...
Страница 51: ...H3 72 01 51 For internal use only 7 1 3 Sequence diagram Steaming EEBD 6600 0...
Страница 53: ...H3 72 01 53 For internal use only Sequence diagram Regenerating EDG EKDG...
Страница 54: ...54 H3 72 01 For internal use only 7 2 2 Sequence diagram Regenerating EEBD 6600 0...
Страница 57: ...H3 72 01 57 For internal use only Sequence diagram Baking like professionals EDG EKDG...
Страница 58: ...58 H3 72 01 For internal use only 7 3 2 Sequence diagram Baking like professionals EEBD 6600 0...
Страница 97: ...H3 72 01 97 For internal use only 11 3 Flow chart Descaling programme EEBD 6600 0...