- 37 -
11. lnner swath board
(Kit no. 103 6200 for GMD 600)
(Kit no. 104 6150 for GMD 700)
The inner swath board set enables reducing the swath width to 1.20 m on the GMD 600 and to 1.25 m on the GMD
700 (approx. 4' on either models).
This set is to be used when combined with the first inner disc with cone and the inner swath wheel (n° 103 6130)
on GMD 600.
On the GMD 700, it must be used in combination with the second high inner cone (n° 104 6130) and the inner swath
wheel (n° 104 6100).
Before assembling the inner swath board, the mounting
bracket (B) must be welded on the cutterbar stiffener
(M) following the instructions on figure 54 and 55.
GMD 600 : X = 430 mm. GMD 700 : X = 720 mm.
Fit the inner swath board support plate (A) on the
mounting bracket (B) with 3 cup square bolts (V)
(M 12 x 30) and 3 self locking nuts (O) (M 12) (torque:
8 daNm / 60 ft.lbs
) (figure 54).
Next fit the inner swath board (C) on the support (A) by
means of a cup square bolt (J) (M 12 x 80), a pressure spring (R), a dished washer (S) and a self-locking nut (T)
(M 12) (figure 54). Do not overtighten the nut so that the board (C) can oscillate around the fixing bolt (J).
To finish the job, fix the swathing stick (D) on the plate (C) with 2 cup square bolts (E) (M 8 x 50) and (F) (M 8 x
30), a spacer (G) and 2 self-locking nuts (H) (M 8) (figure 54).
All manuals and user guides at all-guides.com