RT105M Operator’s Manual
Service - 149
1000 Hour
Change Differential Oil
Change differential oil every 1000 hours.
To change:
1. Remove drain plug (2).
2. Drain fluid and replace plug.
3. Add MPL at fill (1).
Change Transfer Case Oil
Change transfer case oil every 1000 hours.
To change:
1. Remove drain plug (2).
2. Drain oil and replace plug.
3. Add MPL at fill (1) until level with plug (2).
Change Planetary Wheel End Oil
Change wheel end oil every 1000 hours.
To change:
1. Position wheel with plug at bottom.
2. Remove plug.
3. Drain oil.
4. Reposition wheel with plug at midway
position.
5. Add MPL until level reaches plug opening.
6. Replace plug.
Содержание RT105M
Страница 1: ...RT105M Operator s Manual Issue 2 0 Original Instruction 053 2943...
Страница 7: ...Overview 6 RT105M Operator s Manual About This Manual...
Страница 25: ...Safety 24 RT105M Operator s Manual Attachment Safety Alerts...
Страница 61: ...Controls 60 RT105M Operator s Manual Battery Disconnect...
Страница 65: ...Operation Overview 64 RT105M Operator s Manual Leaving Jobsite...
Страница 73: ...Prepare 72 RT105M Operator s Manual Check Supplies and Prepare Equipment...
Страница 79: ...Drive 78 RT105M Operator s Manual Shut Down...
Страница 87: ...Transport 86 RT105M Operator s Manual Retrieve...
Страница 95: ...Backhoe 94 RT105M Operator s Manual Finish Job...
Страница 96: ...RT105M Operator s Manual Trench 95 Trench Chapter Contents Set Up 96 Operate 98 Finish Job 100...
Страница 165: ...Service 164 RT105M Operator s Manual As Needed...
Страница 180: ......
Страница 181: ......
Страница 182: ...RT105M Operator s Manual Service Record 223 Service Record Service Performed Date Hours...
Страница 183: ...Service Record 224 RT105M Operator s Manual Service Performed Date Hours...