Maintenance
W9215-8135-1
133
06/2021
Maintenance
Adhere to the instructions for regular servicing to keep the excavator in good condition.
Refilling the coolant
Check the antifreeze content with an antifreeze tester that is qualified for -25 °C.
Open the engine hood (page 112).
Open the coolant expansion reservoir cap while the engine is
cold and fill pre-mixed coolant up to the FULL mark (1).
If the coolant expansion reservoir was completely empty, check
the coolant level in the radiator.
Remove the radiator cap (2) by turning it anticlockwise.
The coolant level should be at the lower mark of the filler plug;
if not, add coolant.
Refit the radiator cap and close the expansion reservoir.
Close the engine hood and secure it with a padlock.
Danger of cutting and crushing through rotating parts!
The rotating fans can cut into limbs and the rotating belt drive can pull in and crush limbs.
- Switch off the engine before working in the engine room.
- Ensure that the engine and all the engine parts have come to a complete standstill.
- Do not reach into rotating components.
The antifreeze portion of the coolant should not exceed 50%.
Do not open the radiator cap while the engine is still
hot, risk of scalding.
STOP
1
2
STOP
Содержание K008-5
Страница 1: ...GB COMPACT EXCAVATOR MODELS K008 5 U10 5 OPERATING INSTRUCTIONS W9215 8135 1 Original 06 2021...
Страница 14: ...12 W9215 8135 1 06 2021 General information...
Страница 36: ...34 W9215 8135 1 06 2021 Safety rules...
Страница 50: ...48 W9215 8135 1 06 2021 Description of the excavator...
Страница 127: ...Maintenance W9215 8135 1 125 06 2021...
Страница 152: ...150 W9215 8135 1 06 2021 Maintenance...
Страница 154: ...152 W9215 8135 1 06 2021 Safety inspection...
Страница 162: ...160 W9215 8135 1 06 2021 Lifting capacity of the excavator...
Страница 167: ...Accessories W9215 8135 1 165 06 2021...
Страница 168: ......