English
Manual
Limes LA10 / BA1
Absolute Magnetic Length Measurement System
NOTICE!
An error message (Command 80h) replaces the normal acknowledgement
(response) in case of an error.
The error message includes as well communication protocol errors (e.g.
wrong command byte) as object dictionary access errors (e.g. wrong index,
write attempt on a read-only object, wrong data length, etc.).
The error codes are in the device profile (DSP 406).
Example of a service data transmission to and from the Sensor
Master
Sensor
COB-ID für
Command
Index Sub-
max. 4 Byte
SDO (rx)
22h
index
Data
COB-ID für
Command
Index Sub-
SDO (tx)
60h
index
Parameter to
Sensor
Acknowledgement
of receipt from
Sensor
Master
Sensor
COB-ID für
Command
Index Sub-
SDO (rx)
40h
index
COB-ID für
Command
Index Sub-
4 Byte Data
SDO (tx)
43h
index
Request to Sensor
Emission of data by
Sensor
Transmission of parameters from Master to Sensor
Request for parameters from Master to Sensor